EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Time‐Efficient Interleaved Spin Density‐Weighted and Inversion Recovery 23 Na MRI of the Human Calf Muscle at 7 T

Tobias Wilferth iD, Fiona Meyer iD, Jordan M Höhn iD, Michael Uder, Armin M Nagel iD

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70536 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Tobias Wilferth und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany. Hauptthemen laut MEDLINE: Muscle, Skeletal, Magnetic Resonance Imaging, Leg, Image Processing, Computer-Assisted. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Spin density‐weighted (SDW) and inversion recovery (IR) 23 Na MRI provide different sodium contrasts with complementary information. Therefore, the aim was to develop a time‐efficient sequence scheme capable of providing both contrasts by acquiring SDW and IR 23 Na MRI data within a single sequence without additional measurement time.

Methods

In the developed pulse sequence, the conventional 180° inversion pulse was divided into two successive 90° pulses, with an additional readout inserted between them. The sequence was initially evaluated in simulations and phantom measurements. Afterwards, it was applied in calf muscle measurements of six healthy volunteers to assess its practical feasibility and signal characteristics. All 23 Na measurements were acquired at 7 T and compared to standard SDW and IR sequences.

Results

The interleaved SDW/IR sequence yielded image quality and contrast comparable to standard SDW and IR sequences. Phantom experiments showed slightly higher remaining T 1 ‐weighting in the interleaved sequence compared with standard SDW, resulting in only minor changes in image contrast. Fluid suppression was effective across all IR approaches, though efficiency decreased modestly with longer effective inversion pulse lengths. Spin dynamic simulations for IR 23 Na MRI indicated slightly increased sensitivity to fluid suppression artifacts arising from B 0 inhomogeneities in the interleaved sequence. In vivo calf muscle measurements did not reveal significant differences in the mean muscle signal between the interleaved SDW/IR sequence and the corresponding standard sequences.

Conclusion

The proposed interleaved sequence enables simultaneous acquisition of 23 Na SDW and IR contrasts, thereby reducing overall scan time and eliminating the need for co‐registration.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Muscle, SkeletalMagnetic Resonance ImagingLegImage Processing, Computer-AssistedHumansPhantoms, ImagingMaleAdultAlgorithmsFemaleSodiumComputer SimulationHealthy VolunteersSodium IsotopesReproducibility of Results

Stichwörter der Autor:innen

23Na MRI7 Tinterleaved MRIinversion recovery MRIultra‐high field strength

Substanzen

SodiumSodium Isotopes

Autor:innen und Institutionen

  • Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Division of Medical Physics in Radiology, German Cancer Research Centre (DKFZ), Heidelberg, Germany.

ORCID-Profile: Tobias Wilferth, Fiona Meyer, Jordan M Höhn, Armin M Nagel

Förderung

  • Deutsche Forschungsgemeinschaft

Zitieren

APA

Wilferth, T., Meyer, F., Höhn, J. M., Uder, M., & Nagel, A. M. (2026). Time‐Efficient Interleaved Spin Density‐Weighted and Inversion Recovery 23 Na MRI of the Human Calf Muscle at 7 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70536

Vancouver

Wilferth T, Meyer F, Höhn JM, Uder M, Nagel AM. Time‐Efficient Interleaved Spin Density‐Weighted and Inversion Recovery 23 Na MRI of the Human Calf Muscle at 7 T. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70536

BibTeX
@article{Wilferth2026,
  author = {Wilferth, Tobias and Meyer, Fiona and Höhn, Jordan M and Uder, Michael and Nagel, Armin M},
  title = {Time‐Efficient Interleaved Spin Density‐Weighted and Inversion Recovery 23 Na MRI of the Human Calf Muscle at 7 T},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70536}
}
Kostenlos starten →