EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Giving the prostate the boost it needs: Spiral diffusion MRI using a high‐performance whole‐body gradient system for high b ‐values at short echo times

Malwina Molendowska iD, Lars Mueller iD, Fabrizio Fasano iD, Derek K Jones iD, Chantal M W Tax iD, Maria Engel iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30351 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Malwina Molendowska und 5 weiteren Autor:innen. Beteiligte Einrichtung: Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff University, Cardiff, UK. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Prostatic Neoplasms, Prostate, Phantoms, Imaging. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 116 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Sir Henry Wellcome Fellowship, Wellcome Trust, Nederlandse Organisatie voor Wetenschappelijk Onderzoek.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To address key issues of low SNR and image distortions in prostate diffusion MRI (dMRI) by means of using strong gradients, single‐shot spiral readouts and an expanded encoding model for image reconstruction.

Methods

Diffusion‐weighted spin echo imaging with EPI and spiral readouts is performed on a whole‐body system equipped with strong gradients (up to 250 mT/m). An expanded encoding model including static off‐resonance, coil sensitivities, and magnetic field dynamics is employed for image reconstruction. The acquisitions are performed on a phantom and in vivo (one healthy volunteer and one patient with prostate cancer). The resulting images are compared to conventional dMRI EPI with navigator‐based image reconstruction and assessed in terms of their congruence, SNR, tissue contrast, and quantitative parameters.

Results

Using the expanded encoding model, high‐quality images of the prostate gland are obtained across all b ‐values (up to 3 ms/μm 2 ), clearly outperforming the results obtained with conventional image reconstruction. Compared to EPI, spiral imaging provides an SNR gain up to 45% within the gland and even higher in the lesion. In addition, prostate dMRI with single‐shot spirals at submillimeter in‐plane resolution (0.85 mm) is accomplished.

Conclusion

The combination of strong gradients and an expanded encoding model enables imaging of the prostate with unprecedented image quality. Replacing the commonly used EPI with spirals provides the inherent benefit of shorter echo times and superior readout efficiency and results in higher SNR, which is in particular relevant for considered applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diffusion Magnetic Resonance ImagingProstatic NeoplasmsProstatePhantoms, ImagingImage Processing, Computer-AssistedHumansMaleSignal-To-Noise RatioAlgorithmsWhole Body ImagingEcho-Planar Imaging

Stichwörter der Autor:innen

data acquisitiondiffusionfield monitoringimage reconstructionmicrostructureprostate cancer

Autor:innen und Institutionen

  • Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff University, Cardiff, UK.
  • Medical Radiation Physics, Clinical Sciences Lund, Lund University, Lund, Sweden.
  • Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK.
  • Siemens Healthcare Ltd, Camberly, UK.
  • Siemens Healthcare GmbH, Erlangen, Germany.
  • Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands.

ORCID-Profile: Malwina Molendowska, Lars Mueller, Fabrizio Fasano, Derek K Jones, Chantal M W Tax, Maria Engel

Förderung

  • Sir Henry Wellcome Fellowship
  • Wellcome Trust
  • Nederlandse Organisatie voor Wetenschappelijk Onderzoek
  • Siemens Healthineers
  • Engineering and Physical Sciences Research Council

Zitieren

APA

Molendowska, M., Mueller, L., Fasano, F., Jones, D. K., Tax, C. M. W., & Engel, M. (2025). Giving the prostate the boost it needs: Spiral diffusion MRI using a high‐performance whole‐body gradient system for high b ‐values at short echo times. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30351

Vancouver

Molendowska M, Mueller L, Fasano F, Jones DK, Tax CMW, Engel M. Giving the prostate the boost it needs: Spiral diffusion MRI using a high‐performance whole‐body gradient system for high b ‐values at short echo times. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30351

BibTeX
@article{Molendowska2025,
  author = {Molendowska, Malwina and Mueller, Lars and Fasano, Fabrizio and Jones, Derek K and Tax, Chantal M W and Engel, Maria},
  title = {Giving the prostate the boost it needs: Spiral diffusion MRI using a high‐performance whole‐body gradient system for high b ‐values at short echo times},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30351}
}
Kostenlos starten →