EUVIMEDOpdag EUVIMED
Open access

Parallel detection of MRI and 1 H MRSI for multi‐contrast anatomical and metabolic imaging

Robin A de Graaf iD, Monique Thomas, Henk M De Feyter iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30501 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2025. Written by Robin A de Graaf and 2 co-authors. Institution: Magnetic Resonance Research Center (MRRC), Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA. Major MEDLINE topics: Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted, Proton Magnetic Resonance Spectroscopy. Cited 1 times so far (Crossref); 40 references. The full text is freely available in PubMed Central. Funded by: NIBIB NIH HHS, NCI NIH HHS, American Brain Tumor Association.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

MRI and MRSI provide unique and complementary information on anatomy, structure, function, and metabolism. The default strategy for a combined MRI and MRSI study is a sequential acquisition of both modalities, leading to long scan times. As MRI and MRSI primarily detect water and metabolites, respectively, the small frequency difference between resonances can be exploited with frequency‐selective RF pulses to achieve interleaved or parallel detection of MRI and MRSI, without an increase in total scan time.

Methods

Here, we describe the pulse sequence modifications necessary to allow acquisition of T 1 and T 2 ‐weighted MRI and B 0 / B 1 mapping in parallel with MRSI. In general, the MRSI module, including water suppression, can be used unmodified. MRI methods are executed in 3D using 3‐ to 4‐ms frequency‐selective Gaussian RF pulses with acceleration along the third dimension through repetitive small‐angle nutation or multi‐spin‐echo acquisitions.

Results

Phantom experiments demonstrated artifact‐free 3D MRIs. MRSIs in the absence or presence of MRI elements were identical in sensitivity and spectral resolution (line width) and showed consistent water suppression. Parallel MRI‐MRSI was applied to the brains of tumor‐bearing rats in vivo. High‐contrast, high‐sensitivity metabolic MRSI data at 8 μL nominal resolution was acquired in parallel with 3D T 1 ‐weighted, T 2 ‐weighted, and B 0 / B 1 ‐weighted MRIs for an overall scan duration of 30 min.

Conclusion

Multi‐contrast MRIs and MRSI can be acquired in parallel by utilizing the small frequency difference between water and metabolites. This opens the possibility for shorter overall scans times, or the acquisition of higher‐resolution or additional contrast MRIs.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingBrainImage Processing, Computer-AssistedProton Magnetic Resonance SpectroscopyAnimalsRatsPhantoms, ImagingImaging, Three-DimensionalAlgorithms

Author keywords

MRIMRSIfrequency‐selective excitationparallel acquisition

Authors and institutions

  • Magnetic Resonance Research Center (MRRC), Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA.
  • Magnetic Resonance Research Center (MRRC), Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA.

ORCID profiles: Robin A de Graaf, Henk M De Feyter

Funding

  • NIBIB NIH HHS
  • NCI NIH HHS
  • American Brain Tumor Association
  • NIH/NIBIB
  • NIH/NCI
  • National Institute of Biomedical Imaging and Bioengineering

Cite

APA

de Graaf, R. A., Thomas, M., & De Feyter, H. M. (2025). Parallel detection of MRI and 1 H MRSI for multi‐contrast anatomical and metabolic imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30501

Vancouver

de Graaf RA, Thomas M, De Feyter HM. Parallel detection of MRI and 1 H MRSI for multi‐contrast anatomical and metabolic imaging. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30501

BibTeX
@article{deGraaf2025,
  author = {de Graaf, Robin A and Thomas, Monique and De Feyter, Henk M},
  title = {Parallel detection of MRI and 1 H MRSI for multi‐contrast anatomical and metabolic imaging},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30501}
}
Start for free →