In Vivo Meso‐Scale Whole‐Brain Quantitative Imaging With Tailored MRF on the NexGen 7T Scanner
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70234 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Xiaozhi Cao und 20 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Stanford University, Stanford, California, USA. Hauptthemen laut MEDLINE: Brain, Magnetic Resonance Imaging, Imaging, Three-Dimensional, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 68 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NINDS NIH HHS, NICHD NIH HHS.
Abstract (Originalsprache)
Purpose
To push the speed and resolution limit of in vivo quantitative imaging and enable estimation of quantitative tissue parameters of subtle brain structures that were previously difficult to assess.
Methods
This study implemented an efficient quantitative imaging approach, 3D‐SPI MRF, on the NexGen 7T scanner equipped with a high‐performance head‐only gradient and 96‐channel receiver array. To address challenges associated with performing rapid mesoscale MRF on this system, acquisition and reconstruction mitigation methods were developed and incorporated into the MRF framework, including: (i) flip‐angle‐aware dictionary fitting to account for both B 1 + inhomogeneity and voxel‐specific RF frequency response, (ii) gradient imperfection corrections via Skope measurements that incorporates a new per‐TR trajectory rewinder compensation, (iii) incorporation of rapid B 1 + and B 0 mappings into the MRF sequence, and (iv) high‐temporal motion navigation.
Results
Whole‐brain T 1 and T 2 maps were obtained at 560‐μm isotropic resolution within 4 min, where ablation studies demonstrated the necessity of the various mitigation methods implemented in removing bias and artifacts. For comparison, MRF data were acquired using current state‐of‐the‐art method but limited to typical whole‐body gradient specifications to demonstrate that the proposed developments resulted in ∼3× shorter scan time while producing more accurate parameter maps. Data were also acquired at ∼3.8× smaller voxel size, 360‐μm isotropic, using the developed technique, to achieve mesoscale multi‐parameter quantitative mapping in vivo.
Conclusion
Tailored 3D MRF acquisition and reconstruction were developed to enable fast and accurate T 1 and T 2 mapping across the whole‐brain at mesoscale resolution on the NexGen 7T scanner.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Stanford University, Stanford, California, USA.
- Department of Electrical Engineering, Stanford University, Stanford, California, USA.
- Helen Wills Neuroscience Institute, University of California, Berkeley, California, USA.
- Advanced MRI Technologies, Sebastopol, California, USA.
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA.
- Department of Physics and Astronomy, University of California, Irvine, California, USA.
ORCID-Profile: Xiaozhi Cao, Congyu Liao, Zheren Zhu, Zhixing Wang, Zhitao Li, Samantha Ma
Förderung
- NIH HHS
- NINDS NIH HHS
- NICHD NIH HHS
- National Institutes of Health
Zitieren
APA
Cao, X., Beckett, A., Liao, C., Walker, E., Zhu, Z., Qian, Y., Gao, M., Wang, N., Lin, Y., Gong, L., McCready, M. A., Wang, Z., Li, Z., Vu, A., Ma, S., Ramos-Llordén, G., Tian, Q., Kerr, A., Yang, Y., …, & Setsompop, K. (2026). In Vivo Meso‐Scale Whole‐Brain Quantitative Imaging With Tailored MRF on the NexGen 7T Scanner. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70234
Vancouver
Cao X, Beckett A, Liao C, Walker E, Zhu Z, Qian Y, et al. In Vivo Meso‐Scale Whole‐Brain Quantitative Imaging With Tailored MRF on the NexGen 7T Scanner. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70234
BibTeX
@article{Cao2026,
author = {Cao, Xiaozhi and Beckett, Alexander and Liao, Congyu and Walker, Erica and Zhu, Zheren and Qian, Yurui and Gao, Mengze and Wang, Nan and Lin, Yimeng and Gong, Lisong and McCready, Matthew A and Wang, Zhixing and Li, Zhitao and Vu, An and Ma, Samantha and Ramos-Llordén, Gabriel and Tian, Qiyuan and Kerr, Adam and Yang, Yang and Feinberg, David A and Setsompop, Kawin},
title = {In Vivo Meso‐Scale Whole‐Brain Quantitative Imaging With Tailored MRF on the NexGen 7T Scanner},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70234}
}
EUVIMED