Parallel detection of MRI and 1 H MRSI for multi‐contrast anatomical and metabolic imaging
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30501 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2025. Written by Robin A de Graaf and 2 co-authors. Institution: Magnetic Resonance Research Center (MRRC), Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA. Major MEDLINE topics: Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted, Proton Magnetic Resonance Spectroscopy. Cited 1 times so far (Crossref); 40 references. The full text is freely available in PubMed Central. Funded by: NIBIB NIH HHS, NCI NIH HHS, American Brain Tumor Association.
Abstract (original language)
Purpose
MRI and MRSI provide unique and complementary information on anatomy, structure, function, and metabolism. The default strategy for a combined MRI and MRSI study is a sequential acquisition of both modalities, leading to long scan times. As MRI and MRSI primarily detect water and metabolites, respectively, the small frequency difference between resonances can be exploited with frequency‐selective RF pulses to achieve interleaved or parallel detection of MRI and MRSI, without an increase in total scan time.
Methods
Here, we describe the pulse sequence modifications necessary to allow acquisition of T 1 and T 2 ‐weighted MRI and B 0 / B 1 mapping in parallel with MRSI. In general, the MRSI module, including water suppression, can be used unmodified. MRI methods are executed in 3D using 3‐ to 4‐ms frequency‐selective Gaussian RF pulses with acceleration along the third dimension through repetitive small‐angle nutation or multi‐spin‐echo acquisitions.
Results
Phantom experiments demonstrated artifact‐free 3D MRIs. MRSIs in the absence or presence of MRI elements were identical in sensitivity and spectral resolution (line width) and showed consistent water suppression. Parallel MRI‐MRSI was applied to the brains of tumor‐bearing rats in vivo. High‐contrast, high‐sensitivity metabolic MRSI data at 8 μL nominal resolution was acquired in parallel with 3D T 1 ‐weighted, T 2 ‐weighted, and B 0 / B 1 ‐weighted MRIs for an overall scan duration of 30 min.
Conclusion
Multi‐contrast MRIs and MRSI can be acquired in parallel by utilizing the small frequency difference between water and metabolites. This opens the possibility for shorter overall scans times, or the acquisition of higher‐resolution or additional contrast MRIs.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Magnetic Resonance Research Center (MRRC), Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA.
- Magnetic Resonance Research Center (MRRC), Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA.
ORCID profiles: Robin A de Graaf, Henk M De Feyter
Funding
- NIBIB NIH HHS
- NCI NIH HHS
- American Brain Tumor Association
- NIH/NIBIB
- NIH/NCI
- National Institute of Biomedical Imaging and Bioengineering
Cite
APA
de Graaf, R. A., Thomas, M., & De Feyter, H. M. (2025). Parallel detection of MRI and 1 H MRSI for multi‐contrast anatomical and metabolic imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30501
Vancouver
de Graaf RA, Thomas M, De Feyter HM. Parallel detection of MRI and 1 H MRSI for multi‐contrast anatomical and metabolic imaging. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30501
BibTeX
@article{deGraaf2025,
author = {de Graaf, Robin A and Thomas, Monique and De Feyter, Henk M},
title = {Parallel detection of MRI and 1 H MRSI for multi‐contrast anatomical and metabolic imaging},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30501}
}
EUVIMED