A three‐dimensional Magnetic Resonance Spin Tomography in Time‐domain protocol for high‐resolution multiparametric quantitative magnetic resonance imaging
NMR in Biomedicine · 2024
DOI: 10.1002/nbm.5050 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift NMR in Biomedicine, 2024. Verfasst von Hongyan Liu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Computational Imaging Group for MRI Therapy & Diagnostics, Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Multiparametric Magnetic Resonance Imaging. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: China Scholarship Council.
Abstract (Originalsprache)
Magnetic Resonance Spin TomogrAphy in Time‐domain (MR‐STAT) is a multiparametric quantitative MR framework, which allows for simultaneously acquiring quantitative tissue parameters such as T1, T2, and proton density from one single short scan. A typical two‐dimensional (2D) MR‐STAT acquisition uses a gradient‐spoiled, gradient‐echo sequence with a slowly varying RF flip‐angle train and Cartesian readouts, and the quantitative tissue maps are reconstructed by an iterative, model‐based optimization algorithm. In this work, we design a three‐dimensional (3D) MR‐STAT framework based on previous 2D work, in order to achieve better image signal‐to‐noise ratio, higher though‐plane resolution, and better tissue characterization. Specifically, we design a 7‐min, high‐resolution 3D MR‐STAT sequence, and the corresponding two‐step reconstruction algorithm for the large‐scale dataset. To reduce the long acquisition time, Cartesian undersampling strategies such as SENSE are adopted in our transient‐state quantitative framework. To reduce the computational burden, a data‐splitting scheme is designed for decoupling the 3D reconstruction problem into independent 2D reconstructions. The proposed 3D framework is validated by numerical simulations, phantom experiments, and in vivo experiments. High‐quality knee quantitative maps with 0.8 × 0.8 × 1.5 mm 3 resolution and bilateral lower leg maps with 1.6 mm isotropic resolution can be acquired using the proposed 7‐min acquisition sequence and the 3‐min‐per‐slice decoupled reconstruction algorithm. The proposed 3D MR‐STAT framework could have wide clinical applications in the future.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Computational Imaging Group for MRI Therapy & Diagnostics, Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands.
- Department of Radiology, Imaging Division, University Medical Center Utrecht, Utrecht, The Netherlands.
ORCID-Profile: Hongyan Liu, Oscar van der Heide, Edwin Versteeg, Martijn Froeling, Miha Fuderer, Fei Xu
Förderung
- China Scholarship Council
Zitieren
APA
Liu, H., van der Heide, O., Versteeg, E., Froeling, M., Fuderer, M., Xu, F., van den Berg, C. A. T., & Sbrizzi, A. (2024). A three‐dimensional Magnetic Resonance Spin Tomography in Time‐domain protocol for high‐resolution multiparametric quantitative magnetic resonance imaging. NMR in Biomedicine. https://doi.org/10.1002/nbm.5050
Vancouver
Liu H, van der Heide O, Versteeg E, Froeling M, Fuderer M, Xu F, et al. A three‐dimensional Magnetic Resonance Spin Tomography in Time‐domain protocol for high‐resolution multiparametric quantitative magnetic resonance imaging. NMR in Biomedicine. 2024. doi:10.1002/nbm.5050
BibTeX
@article{Liu2024,
author = {Liu, Hongyan and van der Heide, Oscar and Versteeg, Edwin and Froeling, Martijn and Fuderer, Miha and Xu, Fei and van den Berg, Cornelis A T and Sbrizzi, Alessandro},
title = {A three‐dimensional Magnetic Resonance Spin Tomography in Time‐domain protocol for high‐resolution multiparametric quantitative magnetic resonance imaging},
journal = {NMR in Biomedicine},
year = {2024},
doi = {10.1002/nbm.5050}
}
EUVIMED