EUVIMEDEUVIMED entdecken
Open Access

Improving fat saturation robustness in outer extremity MRI with a local shim coil insert

Ziyang Long iD, Hsin-Jung Yang, Nader Binesh, Archana Vadiraj Malagi iD, Yun Shang, Li-Ting Huang, Jeremy Zepeda, Fardad Michael Serry iD, Debiao Li, Hui Han iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30474 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Ziyang Long und 9 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Adipose Tissue, Image Enhancement. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS, NHLBI NIH HHS, National Heart, Lung, and Blood Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

High‐quality fat suppression is essential for various MRI applications. In musculoskeletal imaging, poor fat suppression caused by severe B 0 inhomogeneity can obscure important lesions, potentially leading to inaccurate diagnoses. This problem is particularly exacerbated in off‐isocenter imaging, where conventional shimming using second‐order spherical harmonic shim coils often proves inadequate due to elevated B 0 inhomogeneity. To address this challenge, we configured a simple local shim insert to provide additional localized B 0 shimming for off‐isocenter regions, offering a practical hardware solution.

Methods

We designed and constructed a seven‐channel shim coil and evaluated its performance in comparison to conventional second‐order spherical harmonic shimming within a targeted volume near the scanner bore. The coil was tested with both phantom and in vivo studies using a clinical 3 T MRI scanner.

Results

The improved B 0 homogeneity achieved with the local shim coil significantly enhanced fat saturation (fat–sat) uniformity across the imaged volumes. This improvement was particularly beneficial for areas far from the scanner isocenter, where B 0 inhomogeneity is most severe. Our results indicated a 40% reduction in RMS error of the B 0 field for elbow imaging and 35% for hand imaging, highlighting substantial improvements in B 0 field homogeneity. Additionally, the image quality score increased by 1 point for both hand and elbow images, reflecting enhanced fat–sat quality.

Conclusion

The simple local shim insert we configured improves fat–sat capability in both hand and elbow imaging. It offers the potential for improving off‐isocenter musculoskeletal MRI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingAdipose TissueImage EnhancementPhantoms, ImagingHumansEquipment DesignImage Processing, Computer-AssistedReproducibility of Results

Stichwörter der Autor:innen

MSKfat–satlocal coil shimmingoff‐isocenter

Autor:innen und Institutionen

  • Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.
  • Department of Radiology, Weill Cornell Medicine, New York, New York, USA.
  • Department of Bioengineering, University of California, Los Angeles, Los Angeles, California, USA.
  • Department of Imaging, Cedars-Sinai Medical Center, Los Angeles, California, USA.

ORCID-Profile: Ziyang Long, Archana Vadiraj Malagi, Fardad Michael Serry, Hui Han

Förderung

  • NINDS NIH HHS
  • NHLBI NIH HHS
  • National Heart, Lung, and Blood Institute
  • National Institute of Neurological Disorders and Stroke

Zitieren

APA

Long, Z., Yang, H. J., Binesh, N., Malagi, A. V., Shang, Y., Huang, L. T., Zepeda, J., Serry, F. M., Li, D., & Han, H. (2025). Improving fat saturation robustness in outer extremity MRI with a local shim coil insert. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30474

Vancouver

Long Z, Yang HJ, Binesh N, Malagi AV, Shang Y, Huang LT, et al. Improving fat saturation robustness in outer extremity MRI with a local shim coil insert. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30474

BibTeX
@article{Long2025,
  author = {Long, Ziyang and Yang, Hsin-Jung and Binesh, Nader and Malagi, Archana Vadiraj and Shang, Yun and Huang, Li-Ting and Zepeda, Jeremy and Serry, Fardad Michael and Li, Debiao and Han, Hui},
  title = {Improving fat saturation robustness in outer extremity MRI with a local shim coil insert},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30474}
}
Kostenlos starten →