EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A bootstrapping residuals approach to determine the error in quantitative functional lung imaging

Anne Slawig iD, Andreas Max Weng iD, Simon Veldhoen, Herbert Köstler

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30367 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Anne Slawig und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany. Hauptthemen laut MEDLINE: Lung, Cystic Fibrosis, Magnetic Resonance Imaging, Image Interpretation, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: German Research Foundation, Deutsche Forschungsgemeinschaft.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To implement and validate an algorithm to determine the statistical errors in self‐gated non‐contrast‐enhanced functional lung imaging.

Methods

A bootstrapping residuals approach to determine the error in quantitative functional lung imaging is proposed. Precision and accuracy of the median error over the lungs, as well as reproducibility of the approach were investigated in 7 volunteers. The algorithm was additionally applied to data acquired in a patient with cystic fibrosis.

Results

The obtained bootstrapping error maps appear comparable to the error maps determined from repeated measurements, and median absolute error values for both methods show comparable median errors when reducing the number of averages. In a volunteer in whom 10 consecutive measurements were carried out, the median functional parameters were ventilation = 0.22 mL gas/mL lung tissue, perfusion amplitude = 0.028, perfusion timing = −82 ms, whereas precision and accuracy of the median error were below 3.2 × 10 −3 mL gas/mL lung for ventilation tissue, 4.4 × 10 −4 for perfusion amplitude, and 11 ms for perfusion timing. In the measurement of the patient, low errors in areas with reduced ventilation support the assessment as real defects.

Conclusion

Using a bootstrapping residuals method, the error of functional lung MRI could be determined without the need for repeated measurements. The error values can be determined reproducibly and can be used as a future means of quality control for functional lung MRI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LungCystic FibrosisMagnetic Resonance ImagingImage Interpretation, Computer-AssistedHumansAlgorithmsReproducibility of ResultsMaleFemaleAdultSensitivity and Specificity

Stichwörter der Autor:innen

SENCEFULbootstrappingerror mapsfunctional lung imagingperfusionventilation

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.
  • University Clinic and Outpatient Clinic for Radiology, Medical Physics Group, University Hospital Halle (Saale), Halle, Germany.
  • Halle MR Imaging Core Facility, Medical Faculty, Martin Luther University Halle Wittenberg, Halle, Germany.
  • Division of Pediatric Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.

ORCID-Profile: Anne Slawig, Andreas Max Weng

Förderung

  • German Research Foundation
  • Deutsche Forschungsgemeinschaft

Zitieren

APA

Slawig, A., Weng, A. M., Veldhoen, S., & Köstler, H. (2025). A bootstrapping residuals approach to determine the error in quantitative functional lung imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30367

Vancouver

Slawig A, Weng AM, Veldhoen S, Köstler H. A bootstrapping residuals approach to determine the error in quantitative functional lung imaging. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30367

BibTeX
@article{Slawig2025,
  author = {Slawig, Anne and Weng, Andreas Max and Veldhoen, Simon and Köstler, Herbert},
  title = {A bootstrapping residuals approach to determine the error in quantitative functional lung imaging},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30367}
}
Kostenlos starten →