EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Pulmonary Transit Time Can Be Accurately Quantified From Non‐Arterial Input Function Series in First‐Pass Cardiac Perfusion MRI

Mingyue Zhao, Lexiaozi Fan iD, Kyungpyo Hong, Benjamin H Freed, Jacqueline Urban, Kelvin Chow iD, Li-Yueh Hsu, Daniel C Lee, Daniel Kim iD

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70190 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Mingyue Zhao und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA. Hauptthemen laut MEDLINE: Myocardial Perfusion Imaging, Image Processing, Computer-Assisted, Magnetic Resonance Angiography, Heart. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: American Heart Association, NIH HHS, NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Previous studies suggested that arterial‐input‐function (AIF) images are necessary to avoid signal saturation for pulmonary transit time (PTT) measurements. This study challenges that notion by investigating whether PTT can be accurately measured using blood pool signals from myocardial enhancement (non‐AIF) images during resting first‐pass perfusion MRI.

Methods

This retrospective study included 108 patients, 47 scanned using a research radial perfusion sequence, and 61 scanned with a prototype Cartesian quantitative perfusion (qPerf) sequence with inline PTT calculation. An automated pipeline was developed to compute PTT measurements from blood pool signals extracted from both AIF and non‐AIF images, as well as from gadolinium concentration curves of the AIF images, using three methods: peak‐to‐peak timing, area‐under‐the‐curve (AUC) derived centroids, and curve‐fitting derived centroids.

Results

Peak‐to‐peak PTT showed low bias (0.10–0.56 s; [1.4%–7.4%] of the mean), wide limits of agreement (5.71–7.42 s; [74.5%–109.8%]). In contrast, centroid‐based methods, using both AUC and curve‐fitting approaches, consistently yielded low bias (< 0.49 s; < 6.3%), narrower limits of agreement (1.83–2.84 s; 25.2%–36.8%). These findings indicate that centroid methods offer more precise and reliable PTT estimation across both radial perfusion and qPerf datasets.

Conclusions

PTT can be derived accurately from non‐AIF images using either the AUC or curve‐fitting centroid‐to‐centroid method.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Myocardial Perfusion ImagingImage Processing, Computer-AssistedMagnetic Resonance AngiographyHeartMagnetic Resonance ImagingLungHumansMaleFemaleRetrospective StudiesMiddle AgedAgedAdultAlgorithmsReproducibility of ResultsImage Interpretation, Computer-AssistedContrast MediaPerfusion Magnetic Resonance Imaging

Stichwörter der Autor:innen

area under the curvecurve fittingnon‐arterial input function imagespeak to peakpulmonary transit time

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.
  • Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, USA.
  • Division of Cardiology, Department of Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.
  • Cardiovascular MR R&D, Siemens Medical Solutions USA, Chicago, Illinois, USA.
  • National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.

ORCID-Profile: Lexiaozi Fan, Kelvin Chow, Daniel Kim

Förderung

  • American Heart Association
  • NIH HHS
  • NHLBI NIH HHS
  • Radiological Society of North America
  • National Institutes of Health

Zitieren

APA

Zhao, M., Fan, L., Hong, K., Freed, B. H., Urban, J., Chow, K., Hsu, L. Y., Lee, D. C., & Kim, D. (2026). Pulmonary Transit Time Can Be Accurately Quantified From Non‐Arterial Input Function Series in First‐Pass Cardiac Perfusion MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70190

Vancouver

Zhao M, Fan L, Hong K, Freed BH, Urban J, Chow K, et al. Pulmonary Transit Time Can Be Accurately Quantified From Non‐Arterial Input Function Series in First‐Pass Cardiac Perfusion MRI. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70190

BibTeX
@article{Zhao2026,
  author = {Zhao, Mingyue and Fan, Lexiaozi and Hong, Kyungpyo and Freed, Benjamin H and Urban, Jacqueline and Chow, Kelvin and Hsu, Li-Yueh and Lee, Daniel C and Kim, Daniel},
  title = {Pulmonary Transit Time Can Be Accurately Quantified From Non‐Arterial Input Function Series in First‐Pass Cardiac Perfusion MRI},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70190}
}
Kostenlos starten →