Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Suma Anand und 1 weiteren Autor:innen. Beteiligte Einrichtung: Electrical Engineering and Computer Sciences, University of California, Berkeley, California. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Phantoms, Imaging, Radio Waves. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, GE Healthcare, NIBIB NIH HHS.
Abstract (Originalsprache)
Purpose
To introduce a simple system exploitation with the potential to turn MRI scanners into general‐purpose radiofrequency (RF) motion monitoring systems.
Methods
Inspired by Pilot Tone (PT), this work proposes Beat Pilot Tone (BPT), in which two or more RF tones at arbitrary frequencies are transmitted continuously during the scan. These tones create motion‐modulated standing wave patterns that are sensed by the receiver coil array, incidentally mixed by intermodulation in the receiver chain, and digitized simultaneously with the MRI data. BPT can operate at almost any frequency as long as the intermodulation products lie within the bandwidth of the receivers. BPT's mechanism is explained in electromagnetic simulations and validated experimentally.
Results
Phantom and volunteer experiments over a range of transmit frequencies suggest that BPT may offer frequency‐dependent sensitivity to motion. Using a semi‐flexible anterior receiver array, BPT appears to sense cardiac‐induced body vibrations at microwave frequencies (1.2 GHz). At lower frequencies, it exhibits a similar cardiac signal shape to PT, likely due to blood volume changes. Other volunteer experiments with respiratory, bulk, and head motion show that BPT can achieve greater sensitivity to motion than PT and greater separability between motion types. Basic multiple‐input multiple‐output ( MIMO) operation with simultaneous PT and BPT in head motion is demonstrated using two transmit antennas and a 22‐channel head‐neck coil.
Conclusion
BPT may offer a rich source of motion information that is frequency‐dependent, simultaneous, and complementary to PT and the MRI exam.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Electrical Engineering and Computer Sciences, University of California, Berkeley, California.
ORCID-Profile: Suma Anand, Michael Lustig
Förderung
- NIH HHS
- GE Healthcare
- NIBIB NIH HHS
- National Science Foundation
- NHLBI NIH HHS
- National Institutes of Health
- National Science Foundation of Sri Lanka
Zitieren
APA
Anand, S., & Lustig, M. (2024). Beat Pilot Tone (BPT): Simultaneous MRI and RF motion sensing at arbitrary frequencies. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30150
Vancouver
Anand S, Lustig M. Beat Pilot Tone (BPT): Simultaneous MRI and RF motion sensing at arbitrary frequencies. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30150
BibTeX
@article{Anand2024,
author = {Anand, Suma and Lustig, Michael},
title = {Beat Pilot Tone (BPT): Simultaneous MRI and RF motion sensing at arbitrary frequencies},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30150}
}
EUVIMED