Fast electromagnetic and RF circuit co-simulation for passive resonator field calculation and optimization in MRI
Magnetic Resonance Imaging · 2026
DOI: 10.1016/j.mri.2026.110644 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2026. Verfasst von Zhonghao Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, NIH HHS, National Institutes of Health Office of the Director.
Abstract (Originalsprache)
PURPOSE: Passive resonators have been widely used in MRI to manipulate RF field distributions. However, optimizing these structures using full-wave electromagnetic (EM) simulations is computationally prohibitive, particularly for massive-element passive resonator arrays with many degrees of freedom. METHODS: While EM and RF circuit co-simulation methods have previously been applied to RF coil design, this work presents a co-simulation framework specifically tailored for the analysis and optimization of passive resonators. The framework performs a single full-wave EM simulation in which the resonator's lumped components are replaced by ports, followed by circuit-level computations to evaluate arbitrary capacitor/inductor configurations. This allows integration with a genetic algorithm to rapidly optimize the resonator parameters to enhance B1 fields in a targeted region of interest. RESULTS: The proposed method was validated across three scenarios of increasing complexity: (1) a single-loop passive resonator on a spherical phantom, (2) a two-loop array on a cylindrical phantom, and (3) a two-loop array on a human head model. In all cases, the co-simulation results showed excellent agreement with full-wave EM simulations, with relative errors below 1%. The genetic-algorithm-driven optimization, involving tens of thousands of capacitor combinations, completed in under 5 minutes-whereas equivalent full-wave EM sweeps would require an impractically long computation time. CONCLUSION: To the best of our knowledge, this work represents the first systematic extension of the co-simulation methodology to passive resonator design, enabling fast, accurate, and scalable optimization. The approach significantly reduces computational burden while preserving full-wave accuracy, making it a powerful tool for passive RF structure development in MRI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN, USA.
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA.
- Department of Computer Science, Middle Tennessee State University, Murfreesboro, TN, USA.
- Computational Science and Engineering Division, Oak Ridge National Laboratory, Oak Ridge, TN, USA.
- Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN, USA; Department of Computer Science, Vanderbilt University, Nashville, TN, USA.
- Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN, USA; Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA; Department of R…
Förderung
- NIBIB NIH HHS
- NIH HHS
- National Institutes of Health Office of the Director
- National Institutes of Health
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Zhang, Z., Lu, M., Liang, H., Zu, Z., Gu, Y., Wang, X., Huo, Y., & Yan, X. (2026). Fast electromagnetic and RF circuit co-simulation for passive resonator field calculation and optimization in MRI. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2026.110644
Vancouver
Zhang Z, Lu M, Liang H, Zu Z, Gu Y, Wang X, et al. Fast electromagnetic and RF circuit co-simulation for passive resonator field calculation and optimization in MRI. Magnetic Resonance Imaging. 2026. doi:10.1016/j.mri.2026.110644
BibTeX
@article{Zhang2026,
author = {Zhang, Zhonghao and Lu, Ming and Liang, Hao and Zu, Zhongliang and Gu, Yi and Wang, Xiao and Huo, Yuankai and Yan, Xinqiang},
title = {Fast electromagnetic and RF circuit co-simulation for passive resonator field calculation and optimization in MRI},
journal = {Magnetic Resonance Imaging},
year = {2026},
doi = {10.1016/j.mri.2026.110644}
}
EUVIMED