EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Beat Pilot Tone (BPT): Simultaneous MRI and RF motion sensing at arbitrary frequencies

Suma Anand iD, Michael Lustig iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30150 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Suma Anand und 1 weiteren Autor:innen. Beteiligte Einrichtung: Electrical Engineering and Computer Sciences, University of California, Berkeley, California. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Phantoms, Imaging, Radio Waves. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, GE Healthcare, NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To introduce a simple system exploitation with the potential to turn MRI scanners into general‐purpose radiofrequency (RF) motion monitoring systems.

Methods

Inspired by Pilot Tone (PT), this work proposes Beat Pilot Tone (BPT), in which two or more RF tones at arbitrary frequencies are transmitted continuously during the scan. These tones create motion‐modulated standing wave patterns that are sensed by the receiver coil array, incidentally mixed by intermodulation in the receiver chain, and digitized simultaneously with the MRI data. BPT can operate at almost any frequency as long as the intermodulation products lie within the bandwidth of the receivers. BPT's mechanism is explained in electromagnetic simulations and validated experimentally.

Results

Phantom and volunteer experiments over a range of transmit frequencies suggest that BPT may offer frequency‐dependent sensitivity to motion. Using a semi‐flexible anterior receiver array, BPT appears to sense cardiac‐induced body vibrations at microwave frequencies (1.2 GHz). At lower frequencies, it exhibits a similar cardiac signal shape to PT, likely due to blood volume changes. Other volunteer experiments with respiratory, bulk, and head motion show that BPT can achieve greater sensitivity to motion than PT and greater separability between motion types. Basic multiple‐input multiple‐output ( MIMO) operation with simultaneous PT and BPT in head motion is demonstrated using two transmit antennas and a 22‐channel head‐neck coil.

Conclusion

BPT may offer a rich source of motion information that is frequency‐dependent, simultaneous, and complementary to PT and the MRI exam.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingPhantoms, ImagingRadio WavesHumansMotionEquipment DesignMovementReproducibility of ResultsComputer SimulationAlgorithmsHead

Stichwörter der Autor:innen

microwavemotion sensingpilot toneradiofrequency

Autor:innen und Institutionen

  • Electrical Engineering and Computer Sciences, University of California, Berkeley, California.

ORCID-Profile: Suma Anand, Michael Lustig

Förderung

  • NIH HHS
  • GE Healthcare
  • NIBIB NIH HHS
  • National Science Foundation
  • NHLBI NIH HHS
  • National Institutes of Health
  • National Science Foundation of Sri Lanka

Zitieren

APA

Anand, S., & Lustig, M. (2024). Beat Pilot Tone (BPT): Simultaneous MRI and RF motion sensing at arbitrary frequencies. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30150

Vancouver

Anand S, Lustig M. Beat Pilot Tone (BPT): Simultaneous MRI and RF motion sensing at arbitrary frequencies. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30150

BibTeX
@article{Anand2024,
  author = {Anand, Suma and Lustig, Michael},
  title = {Beat Pilot Tone (BPT): Simultaneous MRI and RF motion sensing at arbitrary frequencies},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30150}
}
Kostenlos starten →