EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Efficient 3D cone trajectory design for improved combined angiographic and perfusion imaging using arterial spin labeling

Qijia Shen iD, Wenchuan Wu iD, Mark Chiew iD, Yang Ji iD, Joseph G Woods iD, Thomas W Okell iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30149 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2024. Written by Qijia Shen and 5 co-authors. Institution: Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom. Major MEDLINE topics: Spin Labels, Imaging, Three-Dimensional, Phantoms, Imaging, Magnetic Resonance Angiography. Cited 7 times so far (Crossref); 39 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIHR Oxford Biomedical Research Centre, Canada Research Chairs, Wellcome Trust.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To improve the spatial resolution and repeatability of a non‐contrast MRI technique for simultaneous time resolved 3D angiography and perfusion imaging by developing an efficient 3D cone trajectory design.

Methods

A novel parameterized 3D cone trajectory design incorporating the 3D golden angle was integrated into 4D combined angiography and perfusion using radial imaging and arterial spin labeling (CAPRIA) to achieve higher spatial resolution and sampling efficiency for both dynamic angiography and perfusion imaging with flexible spatiotemporal resolution. Numerical simulations and physical phantom scanning were used to optimize the cone design. Eight healthy volunteers were scanned to compare the original radial trajectory in 4D CAPRIA with our newly designed cone trajectory. A locally low rank reconstruction method was used to leverage the complementary k‐space sampling across time.

Results

The improved sampling in the periphery of k‐space obtained with the optimized 3D cone trajectory resulted in improved spatial resolution compared with the radial trajectory in phantom scans. Improved vessel sharpness and perfusion visualization were also achieved in vivo. Less dephasing was observed in the angiograms because of the short TE of our cone trajectory and the improved k‐space sampling efficiency also resulted in higher repeatability compared to the original radial approach.

Conclusion

The proposed 3D cone trajectory combined with 3D golden angle ordering resulted in improved spatial resolution and image quality for both angiography and perfusion imaging and could potentially benefit other applications that require an efficient sampling scheme with flexible spatial and temporal resolution.

Subjects

MeSH terms (MEDLINE)

Spin LabelsImaging, Three-DimensionalPhantoms, ImagingMagnetic Resonance AngiographyHumansReproducibility of ResultsAdultMaleAlgorithmsFemalePerfusion ImagingHealthy VolunteersImage Processing, Computer-AssistedComputer Simulation

Author keywords

3D conearterial spin labelingdynamic angiographyperfusion imagingsimultaneous acquisition

Substances

Spin Labels

Authors and institutions

  • Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom.
  • Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada.
  • Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.

ORCID profiles: Qijia Shen, Wenchuan Wu, Mark Chiew, Yang Ji, Joseph G Woods, Thomas W Okell

Funding

  • NIHR Oxford Biomedical Research Centre
  • Canada Research Chairs
  • Wellcome Trust
  • Department of Health
  • Royal Academy of Engineering

Cite

APA

Shen, Q., Wu, W., Chiew, M., Ji, Y., Woods, J. G., & Okell, T. W. (2024). Efficient 3D cone trajectory design for improved combined angiographic and perfusion imaging using arterial spin labeling. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30149

Vancouver

Shen Q, Wu W, Chiew M, Ji Y, Woods JG, Okell TW. Efficient 3D cone trajectory design for improved combined angiographic and perfusion imaging using arterial spin labeling. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30149

BibTeX
@article{Shen2024,
  author = {Shen, Qijia and Wu, Wenchuan and Chiew, Mark and Ji, Yang and Woods, Joseph G and Okell, Thomas W},
  title = {Efficient 3D cone trajectory design for improved combined angiographic and perfusion imaging using arterial spin labeling},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30149}
}
Start for free →