Verifying the Accuracy of Hemodynamic Analysis Using High Spatial Resolution 3D Phase-contrast MR Imaging on a 7T MR System: Comparison with a 3T System
Magnetic Resonance in Medical Sciences · 2025
DOI: 10.2463/mrms.mp.2023-0016 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Magnetic Resonance in Medical Sciences, 2025. Verfasst von Shunsuke Tajima und 5 weiteren Autor:innen. Beteiligte Einrichtung: Radiological Sciences, Department of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japa…. Hauptthemen laut MEDLINE: Phantoms, Imaging, Imaging, Three-Dimensional, Magnetic Resonance Angiography, Hemodynamics. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Institute for Physiological Sciences.
Abstract (Originalsprache)
PURPOSE: Hemodynamics is important in the initiation, growth, and rupture of intracranial aneurysms. Since intracranial aneurysms are small, a high-field MR system with high spatial resolution and high SNR is desirable for this hemodynamic analysis. The purpose of this study was to investigate whether the accuracy of MR fluid dynamic (MRFD) results based on 3D phase-contrast MR (3D PC MR, non-electrocardiogram[ECG]-gated 4D Flow MRI) data from a human cerebrovascular phantom and human healthy subjects obtained by a 7T MR system was superior to those by a 3T MR system. METHODS: 3D PC MR and 3D time of flight MR angiography (3D TOF MRA) imaging were performed on a 3T MR system and a 7T MR system for a human cerebrovascular phantom and 10 healthy human subjects, and MRFD analysis was performed using these data. The MRFD results from each MR system were then compared with the following items based on the computational fluid dynamics (CFD) results: 3D velocity vector field; correlation coefficient (R), angular similarity index (ASI), and magnitude similarity index (MSI) of blood flow velocity vectors. RESULTS: In the MRFD results of 3D velocity vectors of the cerebrovascular phantom, noise-like vectors were observed near the vascular wall on the 3T MR system, but no noise was observed on the 7T MR system, showing results similar to those of CFD. In the MRFD results of the cerebrovascular phantom and healthy subjects, the correlation coefficients R, ASI, and MSI of the 7T MR system were higher than those of the 3T MR system, and ASI and MSI of healthy human subjects were significantly different between the two systems. CONCLUSIONS: The accuracy of high spatial resolution MRFD using the 7T MR system exceeded that of the 3T MR system.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Radiological Sciences, Department of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan.
- Department of Radiological Technology, Nagoya University Hospital, Nagoya, Aichi, Japan.
- Brain & Mind Research Center, Nagoya University, Nagoya, Aichi, Japan.
- Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan.
- Division of Cerebral Integration, National Institute for Physiological Sciences, Okazaki, Aichi, Japan.
- Siemens Healthcare K.K., Tokyo, Japan.
Förderung
- National Institute for Physiological Sciences
Zitieren
APA
Tajima, S., Isoda, H., Fukunaga, M., Komori, Y., Naganawa, S., & Sadato, N. (2025). Verifying the Accuracy of Hemodynamic Analysis Using High Spatial Resolution 3D Phase-contrast MR Imaging on a 7T MR System: Comparison with a 3T System. Magnetic Resonance in Medical Sciences. https://doi.org/10.2463/mrms.mp.2023-0016
Vancouver
Tajima S, Isoda H, Fukunaga M, Komori Y, Naganawa S, Sadato N. Verifying the Accuracy of Hemodynamic Analysis Using High Spatial Resolution 3D Phase-contrast MR Imaging on a 7T MR System: Comparison with a 3T System. Magnetic Resonance in Medical Sciences. 2025. doi:10.2463/mrms.mp.2023-0016
BibTeX
@article{Tajima2025,
author = {Tajima, Shunsuke and Isoda, Haruo and Fukunaga, Masaki and Komori, Yoshiaki and Naganawa, Shinji and Sadato, Norihiro},
title = {Verifying the Accuracy of Hemodynamic Analysis Using High Spatial Resolution 3D Phase-contrast MR Imaging on a 7T MR System: Comparison with a 3T System},
journal = {Magnetic Resonance in Medical Sciences},
year = {2025},
doi = {10.2463/mrms.mp.2023-0016}
}
EUVIMED