EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of 3D BFFE and 3D TRANCE on pulmonary artery imaging with two T-SLIP placement strategies

Li Zhu, Shuai Liu, Xiaoying Tang, Fei Shang, Hong Yu, Yuan Qu, Yan Wang

Magnetic Resonance Imaging · 2025

DOI: 10.1016/j.mri.2024.110274 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Magnetic Resonance Imaging, 2025. Verfasst von Li Zhu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China. Hauptthemen laut MEDLINE: Pulmonary Artery, Imaging, Three-Dimensional, Magnetic Resonance Angiography, Image Interpretation, Computer-Assisted. Die Arbeit nennt 26 Literaturangaben. Gefördert von: Shanghai Municipal Health Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

3D BFFE and TRANCE can provide a visualization of pulmonary vessels without injection of contrast agent. T-SLIP can observe a large area of vessels using an arterial spin labeling technique. 3D BFFE and TRANCE with two T-SLIP placement strategies were compared on pulmonary artery imaging. Ten male and thirteen female healthy volunteers were recruited in the present study. Each subject underwent non-contrast-enhanced pulmonary MRA. Four protocols were involved in the present study as follows: 3D BFFE with T-SLIP covering vena cava (VC) and right atrium and ventricle (RV), respectively; 3D TRANCE with T-SLIP covering VC and RV, respectively. The SNR were measured at eight ROIs, while CNR were measured at five ROIs. The number of visualized branch and image quality were analyzed by two radiologists. The differences of metrics among different imaging strategies were compared. SNR and CNR were compared between two T-SLIP placement strategies using a paired t-test. The branches number and image quality were compared between two T-SLIP placement strategies using a rank-sum test. The agreement of subjective assessment was conducted using a Kappa test. There were significant differences at all ROIs between TRANCE and BFEE with T-SLIP on RV (all P values

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulmonary ArteryImaging, Three-DimensionalMagnetic Resonance AngiographyImage Interpretation, Computer-AssistedHumansFemaleMaleAdultSignal-To-Noise RatioReproducibility of ResultsSpin LabelsYoung Adult

Stichwörter der Autor:innen

Non-contrast enhanced magnetic resonance angiographyPulmonary arteryTime spatial labeling inversion pulse

Substanzen

Spin Labels

Autor:innen und Institutionen

  • Department of Radiology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China.
  • Department of Biomedical Engineering, School of Medical Technology, Beijing Institute of Technology, Beijing, China.
  • Department of Radiology, People's Hospital of Xinjiang Uygur Autonomous Region, Urumqi, Xinjiang Uygur Autonomous Region, China.
  • Department of Radiology, People's Hospital of Xinjiang Uygur Autonomous Region, Urumqi, Xinjiang Uygur Autonomous Region, China. Electronic address: drwangxj@sina.cn.

Förderung

  • Shanghai Municipal Health Commission

Zitieren

APA

Zhu, L., Liu, S., Tang, X., Shang, F., Yu, H., Qu, Y., & Wang, Y. (2025). Comparison of 3D BFFE and 3D TRANCE on pulmonary artery imaging with two T-SLIP placement strategies. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.110274

Vancouver

Zhu L, Liu S, Tang X, Shang F, Yu H, Qu Y, et al. Comparison of 3D BFFE and 3D TRANCE on pulmonary artery imaging with two T-SLIP placement strategies. Magnetic Resonance Imaging. 2025. doi:10.1016/j.mri.2024.110274

BibTeX
@article{Zhu2025,
  author = {Zhu, Li and Liu, Shuai and Tang, Xiaoying and Shang, Fei and Yu, Hong and Qu, Yuan and Wang, Yan},
  title = {Comparison of 3D BFFE and 3D TRANCE on pulmonary artery imaging with two T-SLIP placement strategies},
  journal = {Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1016/j.mri.2024.110274}
}
Kostenlos starten →