High‐resolution anatomical imaging of the fetal brain with a reduced field of view using outer volume suppression
Magnetic Resonance in Medicine · 2024-10 · 92 (4) · 1556-1567
DOI: 10.1002/mrm.30147 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 04.05.2024. Verfasst von MinJung Jang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Weill Cornell Medicine, New York, New York, USA. Hauptthemen laut MEDLINE: Brain, Phantoms, Imaging, Magnetic Resonance Imaging, Artifacts. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health and Welfare, Republic of…, NCATS NIH HHS.
Abstract (Originalsprache)
Purpose
To achieve high‐resolution fetal brain anatomical imaging without introducing image artifacts by reducing the FOV, and to demonstrate improved image quality compared to conventional full‐FOV fetal brain imaging.
Methods
Reduced FOV was achieved by applying outer volume suppression (OVS) pulses immediately prior to standard single‐shot fast spin echo (SSFSE) imaging. In the OVS preparation, a saturation RF pulse followed by a gradient spoiler was repeated three times with optimized flip‐angle weightings and a variable spoiler scheme to enhance signal suppression. Simulations and phantom and in‐vivo experiments were performed to evaluate OVS performance. In‐vivo high‐resolution SSFSE images acquired using the proposed approach were compared with conventional and high‐resolution SSFSE images with a full FOV, using image quality scores assessed by neuroradiologists and calculated image metrics.
Results
Excellent signal suppression in the saturation bands was confirmed in phantom and in‐vivo experiments. High‐resolution SSFSE images with a reduced FOV acquired using OVS demonstrated the improved depiction of brain structures without significant motion and blurring artifacts. The proposed method showed the highest image quality scores in the criteria of sharpness, contrast, and artifact and was selected as the best method based on overall image quality. The calculated image sharpness and tissue contrast ratio were also the highest with the proposed method.
Conclusion
High‐resolution fetal brain anatomical images acquired using a reduced FOV with OVS demonstrated improved image quality both qualitatively and quantitatively, suggesting the potential for enhanced diagnostic accuracy in detecting fetal brain abnormalities in utero.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA.
- Department of Obstetrics and Gynecology, Weill Cornell Medicine, New York, New York, USA.
ORCID-Profile: MinJung Jang, Zungho Zun
Förderung
- NIH HHS
- Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health and Welfare, Republic of…
- NCATS NIH HHS
- NICHD NIH HHS
- National Institutes of Health
- Korea Health Industry Development Institute
Zitieren
APA
Jang, M., Gupta, A., Kovanlikaya, A., Scholl, J. E., & Zun, Z. (2024). High‐resolution anatomical imaging of the fetal brain with a reduced field of view using outer volume suppression. Magnetic Resonance in Medicine, 92(4), 1556-1567. https://doi.org/10.1002/mrm.30147
Vancouver
Jang M, Gupta A, Kovanlikaya A, Scholl JE, Zun Z. High‐resolution anatomical imaging of the fetal brain with a reduced field of view using outer volume suppression. Magnetic Resonance in Medicine. 2024;92(4):1556-1567. doi:10.1002/mrm.30147
BibTeX
@article{Jang2024,
author = {Jang, MinJung and Gupta, Ajay and Kovanlikaya, Arzu and Scholl, Jessica E and Zun, Zungho},
title = {High‐resolution anatomical imaging of the fetal brain with a reduced field of view using outer volume suppression},
journal = {Magnetic Resonance in Medicine},
year = {2024},
volume = {92},
number = {4},
pages = {1556--1567},
doi = {10.1002/mrm.30147}
}
EUVIMED