EUVIMEDEUVIMED entdecken
Crossref

Whole‐brain T 2 mapping with radial sampling and retrospective motion correction at 3T

Nadège Corbin iD, Aurelien J Trotier iD, Serge Anandra, Emile Kadalie iD, Laurence Dallet, Sylvain Miraux, Emeline J Ribot iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30328 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Nadège Corbin und 6 weiteren Autor:innen. Beteiligte Einrichtung: Centre de Résonance Magnétique des Systèmes Biologiques, UMR5536, CNRS, University Bordeaux, Bordeaux, France. Hauptthemen laut MEDLINE: Brain, Phantoms, Imaging, Motion, Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 69 Literaturangaben. Gefördert von: Université de Bordeaux RRI Impact, Agence Nationale de la Recherche, Université de Bordeaux.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Several barriers prevent the use of whole‐brain T 2 mapping in routine use despite increasing interest in this parameter. One of the main barriers is the long scan time resulting in patient discomfort and motion corrupted data. To address this challenge, a method for accurate whole‐brain T 2 mapping with a limited acquisition time and motion correction capabilities is investigated.

Methods

A 3D radial multi‐echo spin‐echo sequence was implemented with optimized sampling trajectory enabling the estimation of intra‐scan motion, subsequently used to correct the raw data. Motion corrected echo images are then reconstructed with linear subspace constrained reconstruction. Experiments were carried out on phantom and volunteers at 3T to evaluate the accuracy of the T 2 estimation, the sensitivity to lesions and the efficiency of the correction on motion corrupted data.

Results

Whole‐brain T 2 mapping acquired in less than 7 min enabled the depiction of lesions in the white matter with longer T 2 . Data retrospectively corrupted with typical motion traces of pediatric patients highly benefited from the motion correction by reducing the error in T 2 estimates within the lesions. All datasets acquired on seven volunteers, with deliberate motion, also showed that motion corrupted T 2 maps could be improved with the retrospective motion correction both at the voxel level and the structure level.

Conclusion

A whole‐brain T 2 mapping sequence with retrospective intra‐scan motion correction and reasonable acquisition time is proposed. The method necessitates advanced iterative reconstruction strategies but no additional navigator, external device, or increased scan time is required.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrainPhantoms, ImagingMotionMagnetic Resonance ImagingAlgorithmsHumansAdultImaging, Three-DimensionalImage Processing, Computer-AssistedArtifactsMaleBrain MappingFemaleReproducibility of ResultsRetrospective Studies

Stichwörter der Autor:innen

T2 mappingmotion correctionradial sampling

Autor:innen und Institutionen

  • Centre de Résonance Magnétique des Systèmes Biologiques, UMR5536, CNRS, University Bordeaux, Bordeaux, France.
  • Biomedical Imaging platform pIBIO, UAR3767, CNRS, Bordeaux, France.

ORCID-Profile: Nadège Corbin, Aurelien J Trotier, Emile Kadalie, Emeline J Ribot

Förderung

  • Université de Bordeaux RRI Impact
  • Agence Nationale de la Recherche
  • Université de Bordeaux

Zitieren

APA

Corbin, N., Trotier, A. J., Anandra, S., Kadalie, E., Dallet, L., Miraux, S., & Ribot, E. J. (2025). Whole‐brain T 2 mapping with radial sampling and retrospective motion correction at 3T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30328

Vancouver

Corbin N, Trotier AJ, Anandra S, Kadalie E, Dallet L, Miraux S, et al. Whole‐brain T 2 mapping with radial sampling and retrospective motion correction at 3T. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30328

BibTeX
@article{Corbin2025,
  author = {Corbin, Nadège and Trotier, Aurelien J and Anandra, Serge and Kadalie, Emile and Dallet, Laurence and Miraux, Sylvain and Ribot, Emeline J},
  title = {Whole‐brain T 2 mapping with radial sampling and retrospective motion correction at 3T},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30328}
}
Kostenlos starten →