Journal article in Magnetic Resonance in Medicine, 2023. Written by Kirsten Miriam Kerkering and 3 co-authors. Institution: Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany. Major MEDLINE topics: Magnetic Resonance Imaging, Image Interpretation, Computer-Assisted. Cited 2 times so far (Crossref); 43 references. The full text is freely available (open access, CC BY 4.0). Funded by: European Metrology Programme for Innovation and Research, Deutsche Forschungsgemeinschaft.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To allow for T1 mapping of the myocardium within 2.3 s for a 2D slice utilizing cardiac motion‐corrected, model‐based image reconstruction.

Methods

Golden radial data acquisition is continuously carried out for 2.3 s after an inversion pulse. In a first step, dynamic images are reconstructed which show both contrast changes due to T1 recovery and anatomical changes due to the heartbeat. An image registration algorithm with a signal model for T1 recovery is applied to estimate non‐rigid cardiac motion. In a second step, estimated motion fields are applied during an iterative model‐based T1 reconstruction. The approach was evaluated in numerical simulations, phantom experiments and in in‐vivo scans in healthy volunteers.

Results

The accuracy of cardiac motion estimation was shown in numerical simulations with an average motion field error of 0.7 ± 0.6 mm for a motion amplitude of 5.1 mm. The accuracy of T1 estimation was demonstrated in phantom experiments, with no significant difference ( p = 0.13) in T1 estimated by the proposed approach compared to an inversion‐recovery reference method. In vivo, the proposed approach yielded 1.3 × 1.3 mm T1 maps with no significant difference ( p = 0.77) in T1 and SDs in comparison to a cardiac‐gated approach requiring 16 s scan time (i.e., seven times longer than the proposed approach). Cardiac motion correction improved the precision of T1 maps, shown by a 40% reduced SD.

Conclusion

We have presented an approach that provides T1 maps of the myocardium in 2.3 s by utilizing both cardiac motion correction and model‐based T1 reconstruction.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingImage Interpretation, Computer-AssistedHumansMyocardiumMotionTomography, X-Ray ComputedPhantoms, ImagingHeartReproducibility of Results

Author keywords

T1 mappingmodel-based reconstructionmotion correctionmultiparametric acquisitionmyocardial tissue characterization

Authors and institutions

  • Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany.
  • Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, DZHK (German Centre for Cardiovascular Research), partner site Berlin,…
  • Working Group Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max-Delbrueck Center for Molecular Medicine and HELIOS Klinikum…
  • Technische Universität Berlin, Department of Biomedical Engineering, Berlin, Germany.

ORCID profiles: Kirsten Miriam Kerkering, Jeanette Schulz-Menger, Tobias Schaeffter, Christoph Kolbitsch

Funding

  • European Metrology Programme for Innovation and Research
  • Deutsche Forschungsgemeinschaft

Cite

APA

Kerkering, K. M., Schulz-Menger, J., Schaeffter, T., & Kolbitsch, C. (2023). Motion‐corrected model‐based reconstruction for 2D myocardial T1 mapping. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29699

Vancouver

Kerkering KM, Schulz-Menger J, Schaeffter T, Kolbitsch C. Motion‐corrected model‐based reconstruction for 2D myocardial T1 mapping. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29699

BibTeX
@article{Kerkering2023,
  author = {Kerkering, Kirsten Miriam and Schulz-Menger, Jeanette and Schaeffter, Tobias and Kolbitsch, Christoph},
  title = {Motion‐corrected model‐based reconstruction for 2D myocardial T1 mapping},
  journal = {Magnetic Resonance in Medicine},
  year = {2023},
  doi = {10.1002/mrm.29699}
}
Start for free →