EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non‐rigid motion‐compensated 3D whole‐heart T 2 mapping in a hybrid 3T PET‐MR system

Alina Schneider iD, Camila Munoz iD, Alina Hua, Sam Ellis, Sami Jeljeli, Karl P Kunze, Radhouene Neji, Andrew J Reader, Eliana Reyes, Tevfik F Ismail, René M Botnar, Claudia Prieto

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.29973 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Alina Schneider und 11 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK. Hauptthemen laut MEDLINE: Myocardium, Myocarditis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust, NHLBI NIH HHS, EPSRC.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Simultaneous PET‐MRI improves inflammatory cardiac disease diagnosis. However, challenges persist in respiratory motion and mis‐registration between free‐breathing 3D PET and 2D breath‐held MR images. We propose a free‐breathing non‐rigid motion‐compensated 3D T 2 ‐mapping sequence enabling whole‐heart myocardial tissue characterization in a hybrid 3T PET‐MR system and provides non‐rigid respiratory motion fields to correct also simultaneously acquired PET data.

Methods

Free‐breathing 3D whole‐heart T 2 ‐mapping was implemented on a hybrid 3T PET‐MRI system. Three datasets were acquired with different T 2 ‐preparation modules (0, 28, 55 ms) using 3‐fold undersampled variable‐density Cartesian trajectory. Respiratory motion was estimated via virtual 3D image navigators, enabling multi‐contrast non‐rigid motion‐corrected MR reconstruction. T 2 ‐maps were computed using dictionary‐matching. Approach was tested in phantom, 8 healthy subjects, 14 MR only and 2 PET‐MR patients with suspected cardiac disease and compared with spin echo reference (phantom) and clinical 2D T 2 ‐mapping (in‐vivo).

Results

Phantom results show a high correlation ( R 2 = 0.996) between proposed approach and gold standard 2D T 2 mapping. In‐vivo 3D T 2 ‐mapping average values in healthy subjects (39.0 ± 1.4 ms) and patients (healthy tissue) (39.1 ± 1.4 ms) agree with conventional 2D T 2 ‐mapping (healthy = 38.6 ± 1.2 ms, patients = 40.3 ± 1.7 ms). Bland–Altman analysis reveals bias of 1.8 ms and 95% limits of agreement (LOA) of −2.4‐6 ms for healthy subjects, and bias of 1.3 ms and 95% LOA of −1.9 to 4.6 ms for patients.

Conclusion

Validated efficient 3D whole‐heart T 2 ‐mapping at hybrid 3T PET‐MRI provides myocardial inflammation characterization and non‐rigid respiratory motion fields for simultaneous PET data correction. Comparable T 2 values were achieved with both 3D and 2D methods. Improved image quality was observed in the PET images after MR‐based motion correction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MyocardiumMyocarditisHumansMagnetic Resonance ImagingMotionImaging, Three-DimensionalPositron-Emission TomographyHeartPhantoms, Imaging

Stichwörter der Autor:innen

3D T2 mappingnon-rigid motion compensationquantitative cardiac MRIwhole heart

Autor:innen und Institutionen

  • School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
  • PET Centre, St Thomas' Hospital, King's College London & Guys and St Thomas' NHS Foundation Trust, London, UK.
  • MR Research Collaborations, Siemens Healthcare Limited, Camberley, UK.
  • Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile.
  • Millenium Institute for Intelligent Healthcare Engineering iHEALTH, Santiago, Chile.

ORCID-Profile: Alina Schneider, Camila Munoz

Förderung

  • Wellcome Trust
  • NHLBI NIH HHS
  • EPSRC
  • National Institute for Health Research (NIHR)
  • Engineering and Physical Sciences Research Council

Zitieren

APA

Schneider, A., Munoz, C., Hua, A., Ellis, S., Jeljeli, S., Kunze, K. P., Neji, R., Reader, A. J., Reyes, E., Ismail, T. F., Botnar, R. M., & Prieto, C. (2024). Non‐rigid motion‐compensated 3D whole‐heart T 2 mapping in a hybrid 3T PET‐MR system. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29973

Vancouver

Schneider A, Munoz C, Hua A, Ellis S, Jeljeli S, Kunze KP, et al. Non‐rigid motion‐compensated 3D whole‐heart T 2 mapping in a hybrid 3T PET‐MR system. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.29973

BibTeX
@article{Schneider2024,
  author = {Schneider, Alina and Munoz, Camila and Hua, Alina and Ellis, Sam and Jeljeli, Sami and Kunze, Karl P and Neji, Radhouene and Reader, Andrew J and Reyes, Eliana and Ismail, Tevfik F and Botnar, René M and Prieto, Claudia},
  title = {Non‐rigid motion‐compensated 3D whole‐heart T 2 mapping in a hybrid 3T PET‐MR system},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.29973}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.