Design and realization of a multi‐coil array for B 0 field control in a compact 1.5T head‐only MRI scanner
Magnetic Resonance in Medicine · 2023
DOI: 10.1002/mrm.29692 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2023. Verfasst von Sebastian Theilenberg und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Columbia University, New York, New York, USA. Hauptthemen laut MEDLINE: Brain, Magnetic Resonance Imaging. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIBIB NIH HHS, NIMH NIH HHS, National Institute of Biomedical Imaging and Bioengineering.
Abstract (Originalsprache)
Purpose
To design and implement a multi‐coil (MC) array for B 0 field generation for image encoding and simultaneous advanced shimming in a novel 1.5T head‐only MRI scanner.
Methods
A 31‐channel MC array was designed following the unique constraints of this scanner design: The vertically oriented magnet is very short, stopping shortly above the shoulders of a sitting subject, and includes a window for the subject to see through. Key characteristics of the MC hardware, the B 0 field generation capabilities, and thermal behavior, were optimized in simulations prior to its construction. The unit was characterized via bench testing. B 0 field generation capabilities were validated on a human 4T MR scanner by analysis of experimental B 0 fields and by comparing images for several MRI sequences acquired with the MC array to those acquired with the system's linear gradients.
Results
The MC system was designed to produce a multitude of linear and nonlinear magnetic fields including linear gradients of up to 10 kHz/cm (23.5 mT/m) with MC currents of 5 A per channel. With water cooling it can be driven with a duty cycle of up to 74% and ramp times of 500 μs. MR imaging experiments encoded with the developed multi‐coil hardware were largely artifact‐free; residual imperfections were predictable, and correctable.
Conclusion
The presented compact multi‐coil array is capable of generating image encoding fields with amplitudes and quality comparable to clinical systems at very high duty cycles, while additionally enabling high‐order B 0 shimming capabilities and the potential for nonlinear encoding fields.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Columbia University, New York, New York, USA.
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, Connecticut, USA.
- Department of Radiology, Columbia University Medical Center, New York, New York, USA.
- Robinson Research Institute, Victoria University of Wellington, Wellington, New Zealand.
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA.
ORCID-Profile: Sebastian Theilenberg, Yun Shang, Chathura Kumaragamage, Ben Parkinson, Mike Garwood, Robin A de Graaf, Christoph Juchem
Förderung
- NIBIB NIH HHS
- NIMH NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Theilenberg, S., Shang, Y., Ghazouani, J., Kumaragamage, C., Nixon, T. W., McIntyre, S., Vaughan, J. T., Parkinson, B., Garwood, M., de Graaf, R. A., & Juchem, C. (2023). Design and realization of a multi‐coil array for B 0 field control in a compact 1.5T head‐only MRI scanner. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29692
Vancouver
Theilenberg S, Shang Y, Ghazouani J, Kumaragamage C, Nixon TW, McIntyre S, et al. Design and realization of a multi‐coil array for B 0 field control in a compact 1.5T head‐only MRI scanner. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29692
BibTeX
@article{Theilenberg2023,
author = {Theilenberg, Sebastian and Shang, Yun and Ghazouani, Jalal and Kumaragamage, Chathura and Nixon, Terence W and McIntyre, Scott and Vaughan, J Thomas and Parkinson, Ben and Garwood, Mike and de Graaf, Robin A and Juchem, Christoph},
title = {Design and realization of a multi‐coil array for B 0 field control in a compact 1.5T head‐only MRI scanner},
journal = {Magnetic Resonance in Medicine},
year = {2023},
doi = {10.1002/mrm.29692}
}
EUVIMED