Homogeneous B0 coil design method for open-access ultra-low field magnetic resonance imaging: A simulation study
Magnetic Resonance Imaging · 2024
DOI: 10.1016/j.mri.2024.07.006 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2024. Verfasst von Tomohiro Karasawa und 3 weiteren Autor:innen. Beteiligte Einrichtung: Technology Research Laboratory, Shimadzu corporation, 3-9-4, Hikaridai, Seika-cho, Soraku-gun 619-0237, Japan. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Equipment Design, Computer Simulation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Abstract (Originalsprache)
A multimodal brain function measurement system integrating functional magnetic resonance imaging (fMRI) and magnetoencephalography (MEG) is expected to be a tool that will provide new insights into neuroscience. To integrate fMRI and MEG, an ultra-low-field MRI (ULF-MRI) scanner that can generate a static magnetic field (B0) with an electromagnetic coil and turn off the B0 during MEG measurements is desirable. While electromagnetic B0 coil has the above advantages, it also has a trade-off between size and the broadness of the magnetic field homogeneity. In this study, we proposed a method for designing a B0 multi-stage circular coil arrangement that determines the number of coils required to maximize magnetic field homogeneity and minimize the total wiring length of the coils. The optimized multi-stage coil arrangement had an external shape of 600 mm in diameter and a maximum height of 600 mm, with an aperture of 600 mm in diameter and 300 mm in height. The magnetic field homogeneity was
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Technology Research Laboratory, Shimadzu corporation, 3-9-4, Hikaridai, Seika-cho, Soraku-gun 619-0237, Japan.
- Office of Institutional Advancement and Communications, Kyoto University, Yoshida-honmachi, Sakyo-ku, Kyoto 606-8501, Japan. Electronic address: kobayashi.tetsuo.2c@kyoto-u.ac.jp.
Zitieren
APA
Karasawa, T., Saikawa, J., Munaka, T., & Kobayashi, T. (2024). Homogeneous B0 coil design method for open-access ultra-low field magnetic resonance imaging: A simulation study. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.07.006
Vancouver
Karasawa T, Saikawa J, Munaka T, Kobayashi T. Homogeneous B0 coil design method for open-access ultra-low field magnetic resonance imaging: A simulation study. Magnetic Resonance Imaging. 2024. doi:10.1016/j.mri.2024.07.006
BibTeX
@article{Karasawa2024,
author = {Karasawa, Tomohiro and Saikawa, Jiro and Munaka, Tatsuya and Kobayashi, Tetsuo},
title = {Homogeneous B0 coil design method for open-access ultra-low field magnetic resonance imaging: A simulation study},
journal = {Magnetic Resonance Imaging},
year = {2024},
doi = {10.1016/j.mri.2024.07.006}
}
EUVIMED