Investigating Setup Error Differences between Conventional and Ultra‐Hypofractionated Whole Pelvis Radiation Therapy: A Secondary Analysis from the HOPE Randomized Clinical Trial
Journal of Applied Clinical Medical Physics · 2026
DOI: 10.1002/acm2.70646 ↗Kurz gefasst
Klinische Studie (Phase II) in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Bryan Schaly und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, London Health Sciences Centre, London, Ontario, Canada. Hauptthemen laut MEDLINE: Brachytherapy, Prostatic Neoplasms, Radiotherapy Planning, Computer-Assisted, Radiotherapy Setup Errors. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: AbbVie CARO Uro-Oncologic Radiation Awards.
Abstract (Originalsprache)
Introduction
The multi‐institutional HOPE trial (NCT04197141) compared conventional (25 fractions over 5 weeks) to ultra‐hypofractionated (5 fractions over 1.5 weeks) whole pelvis radiotherapy for unfavorable intermediate and high/very high‐risk prostate cancer patients treated with brachytherapy boost. Within this randomized controlled trial, we investigated setup errors for clinical target volumes corresponding to the prostate (CTVp) and nodes (CTVn).
Methods
Fifty‐four patients treated within a single institution were analyzed, with 28 treated on the ultra‐hypofractionated arm and 26 on the conventional fractionation arm. Prior to treatment, three fiducial markers were implanted into the prostate for daily cone‐beam computed tomography (CBCT) matching. All plans were delivered using volumetric modulated arc therapy with a uniform 6‐mm PTV margin. For all treatment fractions, average fiducial matching errors were measured for CTVp, while errors to CTVn were determined based on the difference between the treatment position and an automatic match to bone. Asymmetric PTV margins to account for prostatic and nodal setup errors were calculated using the van Herk formalism.
Results
Median (interquartile range [IQR]) 3D errors for CTVp were 1.4 (0.8–2.5) mm for conventional versus 1.2 (0.7–1.9) mm for the ultra‐hypofractionatated arms ( p = 0.013), while for CTVn they were 2.8 (1.6–4.2) mm and 2.9 (2.2–4.4) mm, respectively ( p = 0.07). Between arms, statistically significant differences in setup errors were noted in all directions for CTVp and in the anterior‐posterior direction for CTVn ( p < 0.05). To account for setup error, the required PTV margins in the anterior‐posterior/superior‐inferior/lateral directions were 2.8/3.8/0.8 and 2.7/3.0/1.0 mm for conventional and ultra‐hypofractionated treatments, respectively; for elective nodes, margins were 5.4/4.4/0.7 and 5.7/4.9/1.0 mm, respectively.
Conclusions
The 6‐mm PTV margin around the CTVn is appropriate to account for residual setup error while the margin around the CTVp could be reduced, assuming other sources of error are controlled. The residual 3D errors for the prostate were statistically significantly smaller in the ultra‐fractionated regimen, which was potentially due to longer image matching times and/or the higher percentage of patients treated with a 6‐DOF couch in that arm. However, this came at the expense of slightly larger nodal PTV margins in the ultra‐hypofractionated arm. These findings highlight the need for individual centers to independently quantify their treatment uncertainties, as measurable differences were observed between treatment arms despite identical image guidance protocols.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, London Health Sciences Centre, London, Ontario, Canada.
- Department of Medical Biophysics, Western University, London, Ontario, Canada.
- Department of Health, Aging and Society, McMaster University, Hamilton, Ontario, Canada.
Förderung
- AbbVie CARO Uro-Oncologic Radiation Awards
Zitieren
APA
Schaly, B., Mendez, L. C., Khawaja, M., Black, A., Warner, A., & Hoover, D. A. (2026). Investigating Setup Error Differences between Conventional and Ultra‐Hypofractionated Whole Pelvis Radiation Therapy: A Secondary Analysis from the HOPE Randomized Clinical Trial. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70646
Vancouver
Schaly B, Mendez LC, Khawaja M, Black A, Warner A, Hoover DA. Investigating Setup Error Differences between Conventional and Ultra‐Hypofractionated Whole Pelvis Radiation Therapy: A Secondary Analysis from the HOPE Randomized Clinical Trial. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70646
BibTeX
@article{Schaly2026,
author = {Schaly, Bryan and Mendez, Lucas C and Khawaja, Maha and Black, Alec and Warner, Andrew and Hoover, Douglas A},
title = {Investigating Setup Error Differences between Conventional and Ultra‐Hypofractionated Whole Pelvis Radiation Therapy: A Secondary Analysis from the HOPE Randomized Clinical Trial},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
doi = {10.1002/acm2.70646}
}
EUVIMED