EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of daily residual pancreatic tumor motion for deep‐inspiration breath‐hold radiotherapy

Weihua Mao, Binbin Wu, Kai Ding iD, Sarah Han-Oh, Amol Narang

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70028 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Weihua Mao und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Pancreatic Neoplasms, Breath Holding, Cone-Beam Computed Tomography, Radiotherapy Planning, Computer-Assisted. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Breath‐hold techniques are widely used in radiation therapy to minimize respiratory‐induced tumor or organ‐at‐risk motion. However, residual motion persists, necessitating a reliable daily evaluation method.

Methods

At our institution, fiducial markers serve as surrogates for target localization in pancreatic cancer treatment. We developed an automated method to detect fiducial markers in every projection image of cone‐beam computed tomography (CBCT) scans acquired for patient setup and positioning verification. This method was retrospectively validated using data from nine pancreatic cancer patients.

Results

Residual motion was observed in all patients during breath‐hold maneuvers. Intrafraction target motion in repeated breath‐hold simulation CT scans averaged 1.9 ± 2.2 mm, with a maximum displacement of 8 mm in the superior‐inferior direction. Within a single CBCT scan, residual motion reached up to 7.3 mm, with an average drifting range of 3.8 ± 1.1 mm across 94 CBCT scans. The average standard deviation of drift was 1.5 ± 0.5 mm. Significant drift (1.3 ± 1.2 mm) and inter‐breath‐hold gaps (2.6 ± 2.0 mm) were detected within the same CBCT scan.

Conclusion

Our method enables daily residual motion assessment without additional equipment or extra radiation exposure. This information is critical for refining planning margins in online adaptive radiation therapy, improving treatment precision and patient safety.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pancreatic NeoplasmsBreath HoldingCone-Beam Computed TomographyRadiotherapy Planning, Computer-AssistedRadiotherapy, Image-GuidedHumansRetrospective StudiesRadiotherapy DosageRadiotherapy, Intensity-ModulatedMovementFiducial MarkersImage Processing, Computer-AssistedOrgans at RiskMaleFemaleInhalation

Stichwörter der Autor:innen

CBCT projectionsfiducial markerresidual motion

Autor:innen und Institutionen

  • Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland, USA.

ORCID-Profile: Kai Ding

Zitieren

APA

Mao, W., Wu, B., Ding, K., Han-Oh, S., & Narang, A. (2025). Evaluation of daily residual pancreatic tumor motion for deep‐inspiration breath‐hold radiotherapy. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70028

Vancouver

Mao W, Wu B, Ding K, Han-Oh S, Narang A. Evaluation of daily residual pancreatic tumor motion for deep‐inspiration breath‐hold radiotherapy. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70028

BibTeX
@article{Mao2025,
  author = {Mao, Weihua and Wu, Binbin and Ding, Kai and Han-Oh, Sarah and Narang, Amol},
  title = {Evaluation of daily residual pancreatic tumor motion for deep‐inspiration breath‐hold radiotherapy},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70028}
}