Minimizing human interference in an online fully automated daily adaptive radiotherapy workflow for bladder cancer
Radiation Oncology · 2024
DOI: 10.1186/s13014-024-02526-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Oncology, 2024. Verfasst von Sana Azzarouali und 5 weiteren Autor:innen. Beteiligte Einrichtung: Radiation Oncology, Amsterdam UMC location Vrije Universiteit Amsterdam, De Boelelaan 1117, Amsterdam, The Netherlands. s.azzarouali@amsterdamumc.nl. Hauptthemen laut MEDLINE: Urinary Bladder Neoplasms, Radiotherapy Planning, Computer-Assisted, Workflow, Cone-Beam Computed Tomography. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Varian a Siemens Healthineers Company.
Abstract (Originalsprache)
Purpose
The aim was to study the potential for an online fully automated daily adaptive radiotherapy (RT) workflow for bladder cancer, employing a focal boost and fiducial markers. The study focused on comparing the geometric and dosimetric aspects between the simulated automated online adaptive RT (oART) workflow and the clinically performed workflow.
Methods
Seventeen patients with muscle-invasive bladder cancer were treated with daily Cone Beam CT (CBCT)-guided oART. The bladder and pelvic lymph nodes (CTV elective ) received a total dose of 40 Gy in 20 fractions and the tumor bed received an additional simultaneously integrated boost (SIB) of 15 Gy (CTV boost ). During the online sessions a CBCT was acquired and used as input for the AI-network to automatically delineate the bladder and rectum, i.e. influencers. These influencers were employed to guide the algorithm utilized in the delineation process of the target. Manual adjustments to the generated contours are common during this clinical workflow prior to plan reoptimization and RT delivery. To study the potential for an online fully automated workflow, the oART workflow was repeated in a simulation environment without manual adjustments. A comparison was made between the clinical and automatic contours and between the treatment plans optimized on these clinical (D clin ) and automatic contours (D auto ).
Results
The bladder and rectum delineated by the AI-network differed from the clinical contours with a median Dice Similarity Coefficient of 0.99 and 0.92, a Mean Distance to Agreement of 1.9 mm and 1.3 mm and a relative volume of 100% and 95%, respectively. For the CTV boost these differences were larger, namely 0.71, 7 mm and 78%. For the CTV boost the median target coverage was 0.42% lower for D auto compared to D clin . For CTV elective this difference was 0.03%. The target coverage of D auto met the clinical requirement of the CTV-coverage in 65% of the sessions for CTV boost and 95% of the sessions for the CTV elective .
Conclusions
While an online fully automated daily adaptive RT workflow shows promise for bladder treatment, its complexity becomes apparent when incorporating a focal boost, necessitating manual checks to prevent potential underdosage of the target.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Radiation Oncology, Amsterdam UMC location Vrije Universiteit Amsterdam, De Boelelaan 1117, Amsterdam, The Netherlands. s.azzarouali@amsterdamumc.nl.
- Cancer Center Amsterdam, Cancer Therapy, Treatment and quality of life, Amsterdam, The Netherlands. s.azzarouali@amsterdamumc.nl.
- Radiation Oncology, Amsterdam UMC location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands. s.azzarouali@amsterdamumc.nl.
- Cancer Center Amsterdam, Cancer Therapy, Treatment and quality of life, Amsterdam, The Netherlands.
- Radiation Oncology, Amsterdam UMC location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands.
- Radiation Oncology, Amsterdam UMC location Vrije Universiteit Amsterdam, De Boelelaan 1117, Amsterdam, The Netherlands.
Förderung
- Varian a Siemens Healthineers Company
Zitieren
APA
Azzarouali, S., Goudschaal, K., Visser, J., Daniëls, L., Bel, A., & den Boer, D. (2024). Minimizing human interference in an online fully automated daily adaptive radiotherapy workflow for bladder cancer. Radiation Oncology. https://doi.org/10.1186/s13014-024-02526-2
Vancouver
Azzarouali S, Goudschaal K, Visser J, Daniëls L, Bel A, den Boer D. Minimizing human interference in an online fully automated daily adaptive radiotherapy workflow for bladder cancer. Radiation Oncology. 2024. doi:10.1186/s13014-024-02526-2
BibTeX
@article{Azzarouali2024,
author = {Azzarouali, Sana and Goudschaal, Karin and Visser, Jorrit and Daniëls, Laurien and Bel, Arjan and den Boer, Duncan},
title = {Minimizing human interference in an online fully automated daily adaptive radiotherapy workflow for bladder cancer},
journal = {Radiation Oncology},
year = {2024},
doi = {10.1186/s13014-024-02526-2}
}
EUVIMED