Evaluating intra‐fractional tumor motion in lung stereotactic radiotherapy with deep inspiration breath‐hold
Journal of Applied Clinical Medical Physics · 2024
DOI: 10.1002/acm2.14414 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Weihua Fu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University of Pittsburgh School of Medicine and UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA. Hauptthemen laut MEDLINE: Lung Neoplasms, Breath Holding, Radiotherapy Planning, Computer-Assisted, Radiosurgery. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To evaluate the intra‐fractional tumor motion in lung stereotactic body radiotherapy (SBRT) with deep inspiration breath‐hold (DIBH), and to investigate the adequacy of the current planning target volume (PTV) margins.
Methods
Twenty‐eight lung SBRT patients with DIBH were selected in this study. Among the lesions, twenty‐three were at right or left lower lobe, two at right middle lobe, and three at right or left upper lobe. Post‐treatment gated cone‐beam computed tomography (CBCT) was acquired to quantify the intra‐fractional tumor shift at each treatment. These obtained shifts were then used to calculate the required PTV margin, which was compared with the current applied margin of 5 mm margin in anterior‐posterior (AP) and right‐left (RL) directions and 8 mm in superior‐inferior (SI) direction. The beam delivery time was prolonged with DIBH. The actual beam delivery time with DIBH ( T beam_DIBH ) was compared with the beam delivery time without DIBH ( T beam_wo_DIBH ) for the corresponding SBRT plan.
Results
A total of 113 treatments were analyzed. At six treatments (5.3%), the shifts exceeded the tolerance defined by the current PTV margin. The average shifts were 0.0 ± 1.9 mm, 0.1±1.5 mm, and ‐0.5 ± 3.7 mm in AP, RL, and SI directions, respectively. The required PTV margins were determined to be 4.5, 3.9, and 7.4 mm in AP, RL, and SI directions, respectively. The average T beam_wo_DIBH and T beam_DIBH were 2.4 ± 0.4 min and 3.6 ± 1.5 min, respectively. The average treatment slot for lung SBRT with DIBH was 25.3 ± 7.9 min.
Conclusion
Intra‐fractional tumor motion is the predominant source of treatment uncertainties in CBCT‐guided lung SBRT with DIBH. The required PTV margin should be determined based on data specific to each institute, considering different techniques and populations. Our data indicate that our current applied PTV margin is adequate, and it is possible to reduce further in the RL direction. The time increase of T beam_DIBH , relative to the treatment slot, is not clinically significant.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, University of Pittsburgh School of Medicine and UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA.
ORCID-Profile: Weihua Fu
Zitieren
APA
Fu, W., Zhang, Y., Mehta, K., Chen, A., Musunuru, H. B., Pucci, P., Kubis, J., & Huq, M. S. (2024). Evaluating intra‐fractional tumor motion in lung stereotactic radiotherapy with deep inspiration breath‐hold. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14414
Vancouver
Fu W, Zhang Y, Mehta K, Chen A, Musunuru HB, Pucci P, et al. Evaluating intra‐fractional tumor motion in lung stereotactic radiotherapy with deep inspiration breath‐hold. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14414
BibTeX
@article{Fu2024,
author = {Fu, Weihua and Zhang, Yongqian and Mehta, Kiran and Chen, Alex and Musunuru, Hima Bindu and Pucci, Pietro and Kubis, Jason and Huq, M Saiful},
title = {Evaluating intra‐fractional tumor motion in lung stereotactic radiotherapy with deep inspiration breath‐hold},
journal = {Journal of Applied Clinical Medical Physics},
year = {2024},
doi = {10.1002/acm2.14414}
}