EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Skin marker combined with surface‐guided auto‐positioning for breast DIBH radiotherapy daily initial patient setup: An optimal schedule for both accuracy and efficiency

Jianjun Lai iD, Zhizeng Luo, Lu Jiang, Haili Hu, Chang Gao, Chuanfeng Zhang, Liting Chen, Jing Wu, Zhibing Wu

Journal of Applied Clinical Medical Physics · 2024

DOI: 10.1002/acm2.14319 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Jianjun Lai und 8 weiteren Autor:innen. Beteiligte Einrichtung: Instiute of Intelligent Control and Robotics, Hangzhou Dianzi University, Hangzhou, China. Hauptthemen laut MEDLINE: Breast Neoplasms, Radiotherapy Planning, Computer-Assisted, Radiotherapy Dosage, Cone-Beam Computed Tomography. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Zhejiang Public Welfare Research Program, National Natural Science Foundation of China, Natural Science Foundation of Zhejiang Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and purpose By employing three surface‐guided radiotherapy (SGRT)‐assisted positioning methods, we conducted a prospective study of patients undergoing SGRT‐based deep inspiration breath‐hold (DIBH) radiotherapy using a Sentine/Catalys system. The aim of this study was to optimize the initial positioning workflow of SGRT‐DIBH radiotherapy for breast cancer. Materials and methods A total of 124 patients were divided into three groups to conduct a prospective comparative study of the setup accuracy and efficiency for the daily initial setup of SGRT‐DIBH breast radiotherapy. Group A was subjected to skin marker plus SGRT verification, Group B underwent SGRT optical feedback plus auto‐positioning, and Group C was subjected to skin marker plus SGRT auto‐positioning. We evaluated setup accuracy and efficiency using cone‐beam computed tomography (CBCT) verification data and the total setup time.

Results

In groups A, B, and C, the mean and standard deviation of the translational setup‐error vectors were small, with the highest values of the three directions observed in group A (2.4 ± 1.6, 2.9 ± 1.8, and 2.8 ± 2.1 mm). The rotational vectors in group B (1.8 ± 0.7°, 2.1 ± 0.8°, and 1.8 ± 0.7°) were significantly larger than those in groups A and C, and the Group C setup required the shortest amount of time, at 1.5 ± 0.3 min, while that of Group B took the longest time, at 2.6 ± 0.9 min.

Conclusion

SGRT one‐key calibration was found to be more suitable when followed by skin marker/tattoo and in‐room laser positioning, establishing it as an optimal daily initial set‐up protocol for breast DIBH radiotherapy. This modality also proved to be suitable for free‐breathing breast cancer radiotherapy, and its widespread clinical use is recommended.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Breast NeoplasmsRadiotherapy Planning, Computer-AssistedRadiotherapy DosageCone-Beam Computed TomographyPatient PositioningBreath HoldingRadiotherapy, Intensity-ModulatedHumansFemaleProspective StudiesMiddle AgedAgedRadiotherapy, Image-GuidedRadiotherapy Setup ErrorsAdultPrognosisFiducial MarkersOrgans at Risk

Stichwörter der Autor:innen

DIBHbreast radiotherapysetup efficiency, SGRT

Autor:innen und Institutionen

  • Instiute of Intelligent Control and Robotics, Hangzhou Dianzi University, Hangzhou, China.
  • Department of Radiation Oncology, Zhejiang Hospital, Hangzhou, China.

ORCID-Profile: Jianjun Lai

Förderung

  • Zhejiang Public Welfare Research Program
  • National Natural Science Foundation of China
  • Natural Science Foundation of Zhejiang Province

Zitieren

APA

Lai, J., Luo, Z., Jiang, L., Hu, H., Gao, C., Zhang, C., Chen, L., Wu, J., & Wu, Z. (2024). Skin marker combined with surface‐guided auto‐positioning for breast DIBH radiotherapy daily initial patient setup: An optimal schedule for both accuracy and efficiency. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14319

Vancouver

Lai J, Luo Z, Jiang L, Hu H, Gao C, Zhang C, et al. Skin marker combined with surface‐guided auto‐positioning for breast DIBH radiotherapy daily initial patient setup: An optimal schedule for both accuracy and efficiency. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14319

BibTeX
@article{Lai2024,
  author = {Lai, Jianjun and Luo, Zhizeng and Jiang, Lu and Hu, Haili and Gao, Chang and Zhang, Chuanfeng and Chen, Liting and Wu, Jing and Wu, Zhibing},
  title = {Skin marker combined with surface‐guided auto‐positioning for breast DIBH radiotherapy daily initial patient setup: An optimal schedule for both accuracy and efficiency},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2024},
  doi = {10.1002/acm2.14319}
}