In‐Silico Trial of Same‐Day Simulation‐Free Spatially Fractionated Adaptive Radiotherapy (SF 2 ‐ART)

Dennis N Stanley iD, Alyssa R Birchmeier iD, Carlos E Cardenas iD, Richard A Popple iD, Natalie Viscariello iD, Joel A Pogue iD, Courtney B Stanley iD, Mehran Yusuf iD, Michael Soike iD, Samuel R Marcrom iD, Joseph Harms iD

Journal of Applied Clinical Medical Physics · 2026

DOI: 10.1002/acm2.70517 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Dennis N Stanley und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University of Alabama at Birmingham, Birmingham, Alabama, USA. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Computer Simulation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institutes of Health/National Cancer Institute award, National Institutions of Health/National Cancer Institute award, NCATS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Here we present an in‐silico trial of the feasibility and deliverability of a same‐day, simulation‐free workflow for spatially fractionated adaptive radiotherapy (SF 2 ‐ART) using the Varian Ethos platform. Methods and Materials Ten patients (five thoracic and five extremity), previously treated with spatially fractionated radiotherapy (SFRT), were selected for this in silico trial. A two‐phase regimen was simulated: Phase 1 delivered 12 Gy SBRT to a uniform, predefined high‐dose lattice and 4 Gy to the gross tumor volume (GTV); Phase 2 consisted of 4 additional fractions of 4 Gy to the GTV. The planning workflow was performed entirely in silico, without the need for CT simulation. High‐dose sphere matrices were generated with a custom script and aligned to physician‐defined GTVs. Adaptive plans were created based on CBCT anatomy and evaluated for dosimetric quality, deliverability, and workflow timing. Comparisons were made to the original clinically delivered plans. Mobius3D was used for secondary dose verification.

Results

All 10 cases were successfully replanned using the SF 2 ‐ART workflow without simulation‐based imaging. The entire planning and treatment process, including consultation, contouring, adaptive plan generation, and QA, was performed within a single session. Dosimetric comparisons showed minimal differences between simulation‐free adaptive and clinically delivered plans, with target coverage and normal tissue constraints maintained across all cases. Median total estimated workflow time was 166.4 min.

Conclusions

This in‐silico study demonstrates the feasibility of delivering spatially fractionated SBRT without simulation CT using a same‐day adaptive workflow. The SF 2 ‐ART approach may enable rapid, high‐quality treatment for patients with urgent or symptomatic presentations and supports future prospective clinical implementation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedComputer SimulationHumansDose Fractionation, RadiationRadiotherapy DosageRadiotherapy, Intensity-ModulatedFeasibility StudiesCone-Beam Computed TomographyOrgans at RiskPrognosisWorkflow

Stichwörter der Autor:innen

CT Guided Adaptive RT (CTgART)Online Adaptive RTSimulation FreeSpatially FractionatedVirtual Clinical Study

Autor:innen und Institutionen

  • Department of Radiation Oncology, University of Alabama at Birmingham, Birmingham, Alabama, USA.
  • Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri, USA.

ORCID-Profile: Dennis N Stanley, Alyssa R Birchmeier, Carlos E Cardenas, Richard A Popple, Natalie Viscariello, Joel A Pogue, Courtney B Stanley, Mehran Yusuf, Michael Soike, Samuel R Marcrom, Joseph Harms

Förderung

  • National Institutes of Health/National Cancer Institute award
  • National Institutions of Health/National Cancer Institute award
  • NCATS NIH HHS
  • National Center for Advancing Translational Sciences

Zitieren

APA

Stanley, D. N., Birchmeier, A. R., Cardenas, C. E., Popple, R. A., Viscariello, N., Pogue, J. A., Stanley, C. B., Yusuf, M., Soike, M., Marcrom, S. R., & Harms, J. (2026). In‐Silico Trial of Same‐Day Simulation‐Free Spatially Fractionated Adaptive Radiotherapy (SF 2 ‐ART). Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70517

Vancouver

Stanley DN, Birchmeier AR, Cardenas CE, Popple RA, Viscariello N, Pogue JA, et al. In‐Silico Trial of Same‐Day Simulation‐Free Spatially Fractionated Adaptive Radiotherapy (SF 2 ‐ART). Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70517

BibTeX
@article{Stanley2026,
  author = {Stanley, Dennis N and Birchmeier, Alyssa R and Cardenas, Carlos E and Popple, Richard A and Viscariello, Natalie and Pogue, Joel A and Stanley, Courtney B and Yusuf, Mehran and Soike, Michael and Marcrom, Samuel R and Harms, Joseph},
  title = {In‐Silico Trial of Same‐Day Simulation‐Free Spatially Fractionated Adaptive Radiotherapy (SF 2 ‐ART)},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  doi = {10.1002/acm2.70517}
}
Kostenlos starten →