Three‐dimensional Cherenkov emission surface mapping into the patient coordinate system for spatial delivery verification in EBRT
Journal of Applied Clinical Medical Physics · 2026
DOI: 10.1002/acm2.70566 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Alexander Geiersbach und 5 weiteren Autor:innen. Beteiligte Einrichtung: Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Imaging, Three-Dimensional, Phantoms, Imaging, Image Processing, Computer-Assisted. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, National Science Foundation, NIH HHS.
Abstract (Originalsprache)
Background
Cherenkov imaging provides the ability to visualize beam delivery during radiation therapy treatments in real‐time informing the therapy team about possible deviations from the treatment plan. Current clinical practice with Cherenkov imaging relies on the real‐time view and post‐treatment qualitative assessment of Cherenkov images by therapists, physicists and clinicians who may then perform secondary treatment checks.
Purpose
While Cherenkov images provide new insights into beam location, the limitation is that quantifying the observed deviation is difficult due to the lack of spatial registration of the Cherenkov emission in patient's coordinate space. This work addresses this problem with the first fusion of Cherenkov images with the three‐dimensional patient surface to enable quantitative spatial beam verification in patient coordinate space. By combining multiple camera viewpoints with CT‐sim derived surface coordinates, this system is capable of generating virtual beam's eye view images for objective measurement of beam delivery deviations on patient surfaces. This approach enables automated error detection thresholds and represents the first step toward real‐time, quantitative optical treatment verification and dosimetry.
Methods
Cherenkov images from multiple geometrically calibrated cameras were projected onto Computed Tomography (CT) surface datasets to provide a Cherenkov surface image map on the patient. A raycasting algorithm was utilized to virtually map the Cherenkov surface image into the beam's eye view. To test the ability to quantitatively measure beam versus patient surface deviations from the virtual beam's eye view, a series of 10 × 10 cm 2 6X fields with simulated spatial shifts were delivered to both flat and anthropomorphic phantoms. Virtual beam's eye view images were generated for each shift, and the magnitudes of Cherenkov map shifts were measured with Iterative Closest Point (ICP) and Hausdorff distance metrics with respect to a reference field.
Results
Iterative Closest Point algorithms achieved an average x and y accuracy of 0.5 ± 0.2 mm and 0.3 ± 0.2 mm for the flat phantom and 0.5 mm ± 0.7 mm and 0.3 mm ± 0.2 mm for the anthropomorphic torso phantom. Camera projection error adds up to an additional 0.9 mm of error.
Conclusion
Multi‐view surface mapping of Cherenkov images onto the patient surface mesh enabled quantitative assessment of beam versus topology shifts between fractions, using the Cherenkov emission outline as a beam extent surrogate. We demonstrated the utility and metrics of Cherenkov 3D mapping towards future applications utilizing daily or real‐time surfaces obtained from, for example, cone‐beam CT or surface‐guided radiotherapy (SGRT) systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA.
- Department of Radiation Oncology and Applied Sciences, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire, USA.
Förderung
- NCI NIH HHS
- National Science Foundation
- NIH HHS
- National Institutes of Health
Zitieren
APA
Geiersbach, A., Jermyn, M., Gladstone, D., Jarvis, L., Pogue, B., & Bruza, P. (2026). Three‐dimensional Cherenkov emission surface mapping into the patient coordinate system for spatial delivery verification in EBRT. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70566
Vancouver
Geiersbach A, Jermyn M, Gladstone D, Jarvis L, Pogue B, Bruza P. Three‐dimensional Cherenkov emission surface mapping into the patient coordinate system for spatial delivery verification in EBRT. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70566
BibTeX
@article{Geiersbach2026,
author = {Geiersbach, Alexander and Jermyn, Michael and Gladstone, David and Jarvis, Lesley and Pogue, Brian and Bruza, Petr},
title = {Three‐dimensional Cherenkov emission surface mapping into the patient coordinate system for spatial delivery verification in EBRT},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
doi = {10.1002/acm2.70566}
}
EUVIMED