Technical development and implementation of 3D‐QALAS on a 1.5T MR‐Linac for the brain: A prospective R‐IDEAL stage 0/1 technology development report
Journal of Applied Clinical Medical Physics · 2026
DOI: 10.1002/acm2.70886 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Lucas McCullum und 8 weiteren Autor:innen. Beteiligte Einrichtung: UT MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Houston, Texas, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Phantoms, Imaging, Brain, Particle Accelerators. Die Arbeit nennt 68 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the National Science Foundation (NSF)/National Institutes of Health (NIH) National Cancer Institute (NCI), the NIH National Institute of Dental and Craniofacial Research (NIDCR), the NIH NCI MD Anderson Cancer Center Support Grant (CCSG).
Abstract (Originalsprache)
Background
Quantitative relaxometry of the brain on the integrated MRI / linear accelerator (MR‐Linac) at high isotropic reconstructed resolution is currently limited due to prohibitively long scan times and limited field‐of‐views.
Purpose
The purpose of this study was to assess the technical feasibility of the 3D‐QALAS technique on the 1.5T MR‐Linac which can acquire whole‐brain 1 mm isotropic quantitative T1, T2, and PD maps along with multiple synthetic images in a 7‐minute acquisition time.
Methods
A 1 mm isotropic 3D‐QALAS acquisition was scanned in both phantoms and five healthy volunteers on the 1.5T Elekta Unity MR‐Linac device with scan times around seven minutes. A test‐retest protocol across five independent sessions for the phantom was conducted. The Lin's Concordance Correlation Coefficient (LCCC), repeatability, and reproducibility between measured and reference quantitative T1, T2, and PD values were determined in the phantom. Distortion was also studied. Vendor‐provided reconstruction through SyMRI was performed to extract synthetic images and brain volume metric assessments in the healthy volunteers.
Results
The slope and LCCC between the measured and phantom reference values was 1.02 (1.00), 1.09 (0.90), and 0.99 (1.00) for T1, T2, and PD, respectively. Median distortion across the phantom remained below 2 mm. The repeatability and reproducibility coefficient‐of‐variation (CoV) was under 8% for all measured values. The measured brain volumes in the healthy volunteer was within expected age‐adjusted reference values.
Conclusions
The technical feasibility of using 3D‐QALAS on the integrated 1.5T MR‐Linac was confirmed. Applying this technique to the adaptive radiation therapy workflow of the brain will provide new opportunities to integrate quantitative imaging relaxometry biomarkers at 1 mm isotropic reconstructed resolution.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- UT MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Houston, Texas, USA.
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
ORCID-Profile: Lucas McCullum, Ashley Harrington, Natalie West, Grace Nehring, Ziyu Fu, Ergys Subashi, Brian A Taylor, Ken-Pin Hwang, Clifton D Fuller
Förderung
- the National Science Foundation (NSF)/National Institutes of Health (NIH) National Cancer Institute (NCI)
- the NIH National Institute of Dental and Craniofacial Research (NIDCR)
- the NIH NCI MD Anderson Cancer Center Support Grant (CCSG)
- National Institutes of Health Career Development Award
- Smart and Connected Health (SCH)
- NCI NIH HHS
- NIDCR NIH HHS
- NIDA NIH HHS
Zitieren
APA
McCullum, L., Harrington, A., West, N., Nehring, G., Fu, Z., Subashi, E., Taylor, B. A., Hwang, K. P., & Fuller, C. D. (2026). Technical development and implementation of 3D‐QALAS on a 1.5T MR‐Linac for the brain: A prospective R‐IDEAL stage 0/1 technology development report. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70886
Vancouver
McCullum L, Harrington A, West N, Nehring G, Fu Z, Subashi E, et al. Technical development and implementation of 3D‐QALAS on a 1.5T MR‐Linac for the brain: A prospective R‐IDEAL stage 0/1 technology development report. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70886
BibTeX
@article{McCullum2026,
author = {McCullum, Lucas and Harrington, Ashley and West, Natalie and Nehring, Grace and Fu, Ziyu and Subashi, Ergys and Taylor, Brian A and Hwang, Ken-Pin and Fuller, Clifton D},
title = {Technical development and implementation of 3D‐QALAS on a 1.5T MR‐Linac for the brain: A prospective R‐IDEAL stage 0/1 technology development report},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
doi = {10.1002/acm2.70886}
}
EUVIMED