EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development and application of a novel scintillation gel‐based 3D dosimetry system for radiotherapy

Hua Li, Haijing Jin, Liang He, Xuewen Yan, Hui Zhang, Deyuan Li

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.14615 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Hua Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: Frontier Technology Center, China Institute for Radiation Protection, Taiyuan, Shanxi, China. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Phantoms, Imaging, Algorithms, Radiometry. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Science Fund for Talented Young Scholars of China National Nuclear Corporation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study introduced a novel 3D dosimetry system for radiotherapy in order to address the limitations of traditional quality assurance methods in precision radiotherapy techniques.

Methods

The research required the use of scintillation material, optical measurements, and a dose reconstruction algorithm. The scintillation material, which mimics human soft tissue characteristics, served as a both physical phantom and a radiation detector. The dose distribution inside the scintillator can be converted to light distributions, which were measured by optical cameras from different angles and manifested as pixel values. The proposed dose reconstruction algorithm, LASSO‐TV, effectively reconstructed the dose distribution from pixel values, overcoming challenges such as limited projection directions and large‐scale matrices.

Results

Various clinical plans were tested and validated, including a modified segment from the SBRT plan and IMRT clinical plan. The dosimetry system can execute full 3D dose determinations as a function of time with a spatial resolution of 1–2 mm, enabling high‐resolution measurements for dynamic dose distribution. Comparative analysis with mainstream device MapCHECK2 confirmed the accuracy of the system, with a relative measurement error of within 5%.

Conclusions

Testing and validation results demonstrated the dosimetry system's promising potential for dynamic treatment quality assurance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedPhantoms, ImagingAlgorithmsRadiometryScintillation CountingNeoplasmsImaging, Three-DimensionalHumansRadiotherapy DosageRadiotherapy, Intensity-ModulatedQuality Assurance, Health CareGels

Stichwörter der Autor:innen

3D dosimetryquality assuranceradiotherapyscintillation gel

Substanzen

Gels

Autor:innen und Institutionen

  • Frontier Technology Center, China Institute for Radiation Protection, Taiyuan, Shanxi, China.
  • Shanxi Provincial Key Laboratory for Translational Nuclear Medicine and Precision Protection, Taiyuan, Shanxi, China.

Förderung

  • National Natural Science Foundation of China
  • Science Fund for Talented Young Scholars of China National Nuclear Corporation

Zitieren

APA

Li, H., Jin, H., He, L., Yan, X., Zhang, H., & Li, D. (2025). Development and application of a novel scintillation gel‐based 3D dosimetry system for radiotherapy. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14615

Vancouver

Li H, Jin H, He L, Yan X, Zhang H, Li D. Development and application of a novel scintillation gel‐based 3D dosimetry system for radiotherapy. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.14615

BibTeX
@article{Li2025,
  author = {Li, Hua and Jin, Haijing and He, Liang and Yan, Xuewen and Zhang, Hui and Li, Deyuan},
  title = {Development and application of a novel scintillation gel‐based 3D dosimetry system for radiotherapy},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.14615}
}
Kostenlos starten →