The Spinning Manny Indexed Overlay System for VMAT total body irradiation
Journal of Applied Clinical Medical Physics · 2026
DOI: 10.1002/acm2.70350 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Lawrie Skinner und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Stanford University, Stanford, California, USA. Hauptthemen laut MEDLINE: Radiotherapy, Intensity-Modulated, Whole-Body Irradiation, Radiotherapy Planning, Computer-Assisted, Phantoms, Imaging. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
While modern intensity‐modulated techniques for total body irradiation (TBI) offer superior organ sparing and improved dose coverage compared to conventional TBI, their complexity has limited widespread adoption. Specifically, when treating individuals with Volumetric Modulated Arc Therapy (VMAT‐TBI), a transition between the head‐first‐supine (HFS) and feet‐first‐supine (FFS) orientations is typically required. This study introduces and evaluates the Spinning Manny Indexed Overlay System, an in‐house developed rotational platform designed to streamline VMAT‐TBI treatments.
Methods
The Spinning Manny platform is a carbon fiber overlay that indexes securely to the treatment table, allowing for accurate and reproducible patient rotation. Weight‐bearing assessments, isocenter reproducibility evaluation, and dosimetric characterization through CT imaging and attenuation measurements were made. End‐to‐end testing was performed using anthropomorphic and solid water phantoms, with dosimetric verification using film and thermoluminescent dosimeters (TLDs). The system was clinically implemented for VMAT‐TBI at Stanford University. Workflow efficiency and dose delivery accuracy were assessed through in vivo dosimetry and treatment plan comparisons.
Results
Commissioning tests confirmed the mechanical stability and dosimetric integrity of the Spinning Manny platform. Weight‐bearing tests demonstrated support up to 159 kg, and isocenter reproducibility after rotation was within 1 mm. Attenuation at 6 MV was measured to be 4.3% and 1.3% at beam angles 30° and 90°, respectively, relative to the couch surface. For 10 MV, the attenuation was 3.4% and 1.0% at the same angles. Gamma passing rates in the end‐to‐end tests were 96.9% (3%/2 mm) for the lung regions and 92.6% (5%/3 mm) for the VMAT/AP/PA matchline. Clinical implementation across 136 patients (age range: 1–64 years old, height range: 83.6–197.3 cm) demonstrated efficient workflow integration, with 83% requiring HFS‐to‐FFS transitions. In vivo dosimetry confirmed accurate dose delivery at the matchline (96.1% ± 5.5% relative to prescription dose).
Conclusions
The Spinning Manny Indexed Overlay System effectively addresses a key logistical barrier in VMAT‐TBI by enabling accurate and reproducible HFS‐to‐FFS transitions. Its mechanical stability, low attenuation, and high isocenter reproducibility support its clinical reliability, with successful implementation across patients of varying sizes and ages. By sharing this design, we aim to support the expansion and access of VMAT‐TBI worldwide.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Stanford University, Stanford, California, USA.
- Department of Radiation Oncology, The University of Alabama at Birmingham, Birmingham, Alabama, USA.
- Department of Radiation Oncology, University of California, Irvine, Irvine, California, USA.
ORCID-Profile: Lawrie Skinner, Caressa Hui, Nataliya Kovalchuk
Zitieren
APA
Skinner, L., Simiele, E., Yang, Z., Hui, C., Romero, I., Binkley, M., Hoppe, R., Hiniker, S. M., & Kovalchuk, N. (2026). The Spinning Manny Indexed Overlay System for VMAT total body irradiation. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70350
Vancouver
Skinner L, Simiele E, Yang Z, Hui C, Romero I, Binkley M, et al. The Spinning Manny Indexed Overlay System for VMAT total body irradiation. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70350
BibTeX
@article{Skinner2026,
author = {Skinner, Lawrie and Simiele, Eric and Yang, Zi and Hui, Caressa and Romero, Ignacio and Binkley, Michael and Hoppe, Richard and Hiniker, Susan M and Kovalchuk, Nataliya},
title = {The Spinning Manny Indexed Overlay System for VMAT total body irradiation},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
doi = {10.1002/acm2.70350}
}
EUVIMED