Comparison of Planned Versus Delivered Dose to Children Receiving Total Body Irradiation Using Volumetric Arc Therapy
Pediatric Blood & Cancer · 2026-05 · 73 (5)
DOI: 10.1002/1545-5017.70225 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Pediatric Blood & Cancer, online erschienen am 15.03.2026. Verfasst von Bo Gao und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Fujian Children's Hospital (Fujian Branch of Shanghai Children's Medical Center), College of Clinical Medicine for …. Hauptthemen laut MEDLINE: Whole-Body Irradiation, Radiotherapy, Intensity-Modulated, Radiotherapy Planning, Computer-Assisted, Neoplasms. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: Natural Science Foundation of Fujian Province.
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
Background
Clinical documentation of total body irradiation (TBI) predominantly relies on pretreatment plans rather than actual delivered doses.
Objective
This study systematically characterizes actual dose distributions in volumetric modulated arc therapy TBI (VMAT‐TBI) using real‐world data.
Methods
We retrospectively analyzed treatment plans and daily image‐guided radiation therapy (IGRT) fan‐beam CT (FBCT) images from 47 pediatric patients treated with VMAT‐TBI at two institutions (January 2024–June 2025). Based on the IGRT from the current treatment session, the corresponding positions of the beam centers on the FBCT were determined. The beams were then transferred onto the FBCT for dose recalculation, thereby estimating the actual radiation dose distribution delivered to the patient during that treatment session.
Results
Significant deviations between planned and delivered doses were observed. The 12 Gy/6 fraction regimen showed the greatest variability: median V 90% (PTV volume receiving ≥90% prescribed dose) decreased from 98.3% to 97.8% (−0.7%), V 100% declined from 93.5% to 92.5% (−1.0%), and V 110% increased from 8.0% to 19.0% (+11.0%). No regions received >120% of the prescribed dose. Mean lung dose reached 83.0% of the prescription in the 1 Gy regimen (+5.5% deviation) and 70.5% in the 12 Gy regimen (+5.0% deviation). All kidney doses remained below 9 Gy. Both planned and delivered doses remained within clinically acceptable ranges for all regimens.
Conclusion
This first systematic evaluation of actual delivered doses in VMAT‐TBI confirms the technique's dosimetric precision and safety. Our findings provide actionable evidence for optimizing VMAT‐TBI implementation in clinical practice, particularly regarding dose verification protocols and adaptive strategies for low‐dose regimens.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Fujian Children's Hospital (Fujian Branch of Shanghai Children's Medical Center), College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuz…
- Department of Radiation Oncology, Shanghai Children's Medical Center Affiliated to Shanghai Jiaotong University School of Medicine Institute, Shanghai, China.
- Hunan Provincial Hospital of Integrated Traditional Chinese and Western Medicine, Changsha, Hunan, China.
- Department of Radiation Oncology, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Förderung
- Natural Science Foundation of Fujian Province
Zitieren
APA
Gao, B., Hong, Y., Yan, J., Chen, X., Tan, S., Zhu, Y., Liu, Y., Chen, H., & Lei, Z. (2026). Comparison of Planned Versus Delivered Dose to Children Receiving Total Body Irradiation Using Volumetric Arc Therapy. Pediatric Blood & Cancer, 73(5). https://doi.org/10.1002/1545-5017.70225
Vancouver
Gao B, Hong Y, Yan J, Chen X, Tan S, Zhu Y, et al. Comparison of Planned Versus Delivered Dose to Children Receiving Total Body Irradiation Using Volumetric Arc Therapy. Pediatric Blood & Cancer. 2026;73(5). doi:10.1002/1545-5017.70225
BibTeX
@article{Gao2026,
author = {Gao, Bo and Hong, Yaling and Yan, Junjin and Chen, Xiwei and Tan, Suhua and Zhu, Yutao and Liu, Yan and Chen, Haiyan and Lei, Zhanquan},
title = {Comparison of Planned Versus Delivered Dose to Children Receiving Total Body Irradiation Using Volumetric Arc Therapy},
journal = {Pediatric Blood & Cancer},
year = {2026},
volume = {73},
number = {5},
doi = {10.1002/1545-5017.70225}
}
EUVIMED