EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Total body irradiation: A transition from a Co‐60 treatment unit to an IMRT lateral‐field extended‐SAD technique

Anastasia Kolokotronis, Malik Brunet-Benkhoucha, Étienne Roussin, Julie St-Pierre, Eve-Lyne Marchand, Maryse Bernard

Journal of Applied Clinical Medical Physics · 2024

DOI: 10.1002/acm2.14430 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Anastasia Kolokotronis und 5 weiteren Autor:innen. Beteiligte Einrichtung: Département de Radio-oncologie, CIUSSS de l'Est-de-L'Île-de-Montréal, Hôpital Maisonneuve-Rosemont, Montréal, Quebec, Canada. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated, Whole-Body Irradiation, Radiotherapy Dosage. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this work was to detail our center's experience in transitioning from a Co‐60 treatment technique to an intensity modulated radiation therapy (IMRT) based lateral‐field extended source‐to‐axis distance (e‐SAD) technique for total body irradiation (TBI). Materials and Methods An existing beam model in RayStation v.10A was validated for the use of e‐SAD TBI treatments. Data were acquired with an Elekta Synergy linear accelerator (LINAC) at an extended source‐to‐surface distance of 365 cm with an 18 MV beam. Beam model validation measurements included percentage depth dose (PDD), profile data, surface dose, build‐up region and transmission measurements. End‐to‐end testing was carried out using an anthropomorphic phantom. Treatments were performed in a supine position in a whole‐body Vac‐Lok at an e‐SAD of 400 cm with a beam spoiler 10 cm from the couch. Planning was achieved using IMRT, where multi‐leaf collimators were used to modulate the beam and shield the organs at risk. Beam's eye view projection images were used for in‐room patient positioning and in‐vivo dosimetry was performed for every treatment.

Results

The percent difference between the measured and calculated PDD and profiles was less than 2% at all locations. Surface dose was 83.8% of the maximum dose with the beam spoiler at a 10 cm distance from the phantom. The largest percent difference between the treatment planning system (TPS) and measured data within the anthropomorphic phantom was approximately 2%. In‐vivo dosimetry measurements yielded results within the 5% institutional threshold.

Conclusion

In 2022, 17 patients were successfully treated using the new IMRT‐based lateral‐field e‐SAD TBI technique. The resulting clinical plans respected the institutional standard. The commissioning process, as well as the treatment planning and delivery aspects were described in this work with the intention of supporting other clinics in implementing this treatment method.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedRadiotherapy, Intensity-ModulatedWhole-Body IrradiationRadiotherapy DosagePhantoms, ImagingParticle AcceleratorsOrgans at RiskCobalt RadioisotopesHumansNeoplasms

Stichwörter der Autor:innen

TBI commissioningTBI treatment planningextended‐SSD IMRTtotal body irradiation (TBI)

Substanzen

Cobalt RadioisotopesCobalt-60

Autor:innen und Institutionen

  • Département de Radio-oncologie, CIUSSS de l'Est-de-L'Île-de-Montréal, Hôpital Maisonneuve-Rosemont, Montréal, Quebec, Canada.

Zitieren

APA

Kolokotronis, A., Brunet-Benkhoucha, M., Roussin, É., St-Pierre, J., Marchand, E. L., & Bernard, M. (2024). Total body irradiation: A transition from a Co‐60 treatment unit to an IMRT lateral‐field extended‐SAD technique. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14430

Vancouver

Kolokotronis A, Brunet-Benkhoucha M, Roussin É, St-Pierre J, Marchand EL, Bernard M. Total body irradiation: A transition from a Co‐60 treatment unit to an IMRT lateral‐field extended‐SAD technique. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14430

BibTeX
@article{Kolokotronis2024,
  author = {Kolokotronis, Anastasia and Brunet-Benkhoucha, Malik and Roussin, Étienne and St-Pierre, Julie and Marchand, Eve-Lyne and Bernard, Maryse},
  title = {Total body irradiation: A transition from a Co‐60 treatment unit to an IMRT lateral‐field extended‐SAD technique},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2024},
  doi = {10.1002/acm2.14430}
}
Kostenlos starten →