An automated daily QA strategy for dosimetry and imaging guidance check of a novel PET/CT ring gantry linac

Sagar Ghimire, Yang Kyun Park, Grant Gibbard, Jun Tan, Thomas I Banks iD, Chenyang Shen iD, Rameshwar Prasad, Tingliang Zhuang, Andrew Godley, Steve B Jiang, Bin Cai

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70309 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Sagar Ghimire und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Radiotherapy Planning, Computer-Assisted, Particle Accelerators, Quality Assurance, Health Care. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The RefleXion X1 is a novel PET/CT‐guided ring gantry linac that introduces unique geometry and workflow compared to conventional systems. Existing QA guidelines (AAPM TG‐142, 148, 306) cover standard linacs and tomotherapy but do not address this platform's needs. Therefore, an automated daily QA solution is required to ensure accurate output, imaging guidance, and couch positioning, which motivated the development and evaluation of the workflow presented in this study.

Purpose

To develop and evaluate an automated, efficient, and comprehensive daily quality assurance (QA) workflow for a novel PET/CT‐guided ring gantry linear accelerator (RefleXion X1), incorporating tests for dosimetry, imaging guidance, and couch positioning accuracy.

Methods

An IMRT QA plan was designed following the CT scan of the TomoDose 2D diode detector array (Sun Nuclear, Melbourne, FL) within the RefleXion treatment planning system (TPS). Several spherical targets of varying sizes were contoured to conform the dose distribution to these targets and evaluate beam output, laser localization, profile constancy, and CT‐MV isocenter coincidence. Linear models correlating spatial location of dose peak with intentional shifts in different directions were developed and integrated into an in‐house analysis software, iQA, written in C#. The software was validated for robustness and successfully implemented in clinical practice.

Results

Validation with 42 intentional shifts showed submillimeter accuracy, with mean deviations of 0.2 mm (X), 0.1 mm (Y), and 0.79 mm (Z), and R 2 values ≥ 0.98. Over 1 year, daily QA data showed stable output constancy (1.006 ± 0.016), left/right target dose constancy (1.007 ± 0.005 and 0.996 ± 0.004), and consistent CT‐MV isocenter offsets (–0.335 ± 0.23 mm in X, 0.19 ± 0.19 mm in Y, and –0.544 ± 0.36 mm in Z). The software also detected a gradual output drift in between, prompting a timely linac adjustment.

Conclusion

This fully automated, single‐delivery QA workflow enables efficient and robust evaluation of multiple IGRT performance parameters. It improves standardization, reduces human error, and reliably monitors long‐term machine stability. The tools and methodology may be adopted by other clinics seeking a practical and automated daily QA solution. Future developments will focus on incorporating PET QA and rotational couch validations to further enhance the system's comprehensiveness and adaptability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron Emission Tomography Computed TomographyRadiotherapy Planning, Computer-AssistedParticle AcceleratorsQuality Assurance, Health CarePhantoms, ImagingImage Processing, Computer-AssistedRadiometryNeoplasmsRadiotherapy, Image-GuidedHumansRadiotherapy, Intensity-ModulatedRadiotherapy Dosage

Stichwörter der Autor:innen

Daily QAPET‐linacRefleXion X1image‐guided radiotherapy

Autor:innen und Institutionen

  • Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
  • RefleXion Medical, Hayward, California, USA.
  • Department of Radiation Oncology, Mayo Clinic, Jasonville, Florida, USA.

ORCID-Profile: Thomas I Banks, Chenyang Shen

Zitieren

APA

Ghimire, S., Park, Y. K., Gibbard, G., Tan, J., Banks, T. I., Shen, C., Prasad, R., Zhuang, T., Godley, A., Jiang, S. B., & Cai, B. (2025). An automated daily QA strategy for dosimetry and imaging guidance check of a novel PET/CT ring gantry linac. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70309

Vancouver

Ghimire S, Park YK, Gibbard G, Tan J, Banks TI, Shen C, et al. An automated daily QA strategy for dosimetry and imaging guidance check of a novel PET/CT ring gantry linac. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70309

BibTeX
@article{Ghimire2025,
  author = {Ghimire, Sagar and Park, Yang Kyun and Gibbard, Grant and Tan, Jun and Banks, Thomas I and Shen, Chenyang and Prasad, Rameshwar and Zhuang, Tingliang and Godley, Andrew and Jiang, Steve B and Cai, Bin},
  title = {An automated daily QA strategy for dosimetry and imaging guidance check of a novel PET/CT ring gantry linac},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70309}
}
Kostenlos starten →