Intra‐ and inter‐fractional variations of tumors with fiducial markers measured using respiratory‐correlated computed tomography images for respiratory gated lung stereotactic body radiation therapy
Journal of Applied Clinical Medical Physics · 2024
DOI: 10.1002/acm2.14280 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Yuki Manabe und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Yamaguchi University Graduate School of Medicine, Ube, Yamaguchi, Japan. Hauptthemen laut MEDLINE: Radiosurgery, Lung Neoplasms, Fiducial Markers, Radiotherapy Planning, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
This study evaluated the intra‐ and inter‐fractional variation of tumors with fiducial markers (FMs), relative to the tumor‐FM distance, to establish how close an FM should be inserted for respiratory‐gated stereotactic body radiation therapy (RG‐SBRT).
Methods
Forty‐five lung tumors treated with RG‐SBRT were enrolled. End‐expiratory computed tomography (CT) (CT plan ) and four‐dimensional‐CT (4D‐CT) scans were obtained for planning. End‐expiratory CT (CT fr ) scanning was performed before each fraction. The FMs were divided into two groups based on the median tumor‐FM distance in the CT plan (D p ). For the intra‐fractional variation, the correlations between the corresponding tumor and FM intra‐fractional motions, defined as the centroid coordinates of those in each 0–90% phase, with the 50% phase of 4D‐CT as the origin, were calculated in the left‐right, anterior‐posterior, and superior‐inferior directions. Furthermore, the maximum difference in the tumor‐FM distance in each phase of 4D‐CT scan, based on those in the 50% phase of 4D‐CT scan (D max ), was obtained. Inter‐fractional variation was defined as the maximum distance between the tumors in CT plan and CT fr , when the CT scans were fused based on each FM or vertebra.
Results
The median D p was 26.1 mm. While FM intra‐fractional motions were significantly and strongly correlated with the tumor intra‐fractional motions in only anterior‐posterior and superior‐inferior directions for the D p > 26 mm group, they were significantly and strongly correlated in all directions for the D p ≤ 26 mm group. In all directions, D max values of the D p ≤ 26 mm group were lower than those of the D p > 26 mm group. The inter‐fractional variations based on the D p ≤ 26 mm were smaller than those on the D p > 26 mm and on the vertebra in all directions.
Conclusions
Regarding intra‐ and inter‐fractional variation, FMs for D p ≤ 26 mm can increase the accuracy for RG‐SBRT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Yamaguchi University Graduate School of Medicine, Ube, Yamaguchi, Japan.
ORCID-Profile: Takehiro Shiinoki
Zitieren
APA
Manabe, Y., Shiinoki, T., Fujimoto, K., Ueda, K., Karita, M., Ono, T., Kajima, M., & Tanaka, H. (2024). Intra‐ and inter‐fractional variations of tumors with fiducial markers measured using respiratory‐correlated computed tomography images for respiratory gated lung stereotactic body radiation therapy. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14280
Vancouver
Manabe Y, Shiinoki T, Fujimoto K, Ueda K, Karita M, Ono T, et al. Intra‐ and inter‐fractional variations of tumors with fiducial markers measured using respiratory‐correlated computed tomography images for respiratory gated lung stereotactic body radiation therapy. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14280
BibTeX
@article{Manabe2024,
author = {Manabe, Yuki and Shiinoki, Takehiro and Fujimoto, Koya and Ueda, Kazushi and Karita, Masako and Ono, Taiki and Kajima, Miki and Tanaka, Hidekazu},
title = {Intra‐ and inter‐fractional variations of tumors with fiducial markers measured using respiratory‐correlated computed tomography images for respiratory gated lung stereotactic body radiation therapy},
journal = {Journal of Applied Clinical Medical Physics},
year = {2024},
doi = {10.1002/acm2.14280}
}