Dynamic range and optimization strategies for radiochromic film calibration using gradient radiation fields
Journal of Applied Clinical Medical Physics · 2024
DOI: 10.1002/acm2.14481 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Stevan Pecic und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Physics, University of Belgrade, Belgrade, Serbia. Hauptthemen laut MEDLINE: Film Dosimetry, Radiotherapy Dosage, Algorithms, Radiotherapy Planning, Computer-Assisted. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Education, Science, and Technological Development of the Republic of Serbia, Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
This investigation aimed to optimize gradient positioning for radiochromic film calibration to facilitate a uniform distribution of calibration points. The study investigated the influence of various parameters on gradient dose profiles generated by a physical wedge, assessing their impact on the field's dose dynamic range, a scalar quantity representing the span of absorbed doses. Numerical parameterization of the physical wedge profile was used to visualize and quantify the impact of field size, depth, and energy on the dynamic range of dose gradients. This concept enabled the optimization of the gradient positioning and estimation of the necessary number of exposures for the desired calibration dose range. An optimization algorithm based on histogram bin height minimization was developed and presented. The maximum dynamic range was achieved with a 20 20 field size at 5 cm depth. Optimization of wedge gradient positioning yielded the most uniform dose distribution with 7 exposures for the [1,10] Gy range and 8 exposures for the [1,20] Gy range. Film calibration using gradients centered at 1.6, 3, 3.5, and 7 Gy central axis (CAX), obtained through optimized gradient positioning, was showcased. The presented work demonstrates the potential for an improved film calibration process, with efficient material utilization and enhanced dosimetric accuracy for clinical applications. While the method was described for the use of a physical wedge, the methodology can be easily extended to the use of a more convenient dynamic wedge.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Physics, University of Belgrade, Belgrade, Serbia.
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
- Institute of Oncology and Radiology of Serbia, Belgrade, Serbia.
- Medical Physics Unit, McGill University, Montreal, Canada.
- Department of Radiation Oncology, SMBD Jewish General Hospital, Montreal, Canada.
ORCID-Profile: Stevan Pecic, Strahinja Stojadinovic, Borko Nidzovic
Förderung
- Ministry of Education, Science, and Technological Development of the Republic of Serbia
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Pecic, S., Belca, I., Stojadinovic, S., Nidzovic, B., Vicic, M., & Devic, S. (2024). Dynamic range and optimization strategies for radiochromic film calibration using gradient radiation fields. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14481
Vancouver
Pecic S, Belca I, Stojadinovic S, Nidzovic B, Vicic M, Devic S. Dynamic range and optimization strategies for radiochromic film calibration using gradient radiation fields. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14481
BibTeX
@article{Pecic2024,
author = {Pecic, Stevan and Belca, Ivan and Stojadinovic, Strahinja and Nidzovic, Borko and Vicic, Milos and Devic, Slobodan},
title = {Dynamic range and optimization strategies for radiochromic film calibration using gradient radiation fields},
journal = {Journal of Applied Clinical Medical Physics},
year = {2024},
doi = {10.1002/acm2.14481}
}
EUVIMED