FilmQADose: Open‐source software for radiochromic film dosimetry
Journal of Applied Clinical Medical Physics · 2026
DOI: 10.1002/acm2.70602 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Eduardo Herrera-Alba und 4 weiteren Autor:innen. Beteiligte Einrichtung: Physics Department, Universidad de los Andes, Bogotá, Colombia. Hauptthemen laut MEDLINE: Film Dosimetry, Software, Radiotherapy Planning, Computer-Assisted, Quality Assurance, Health Care. Die Arbeit nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Physics Department and the Faculty of Science of Universidad de los Andes, Bogotá.
Abstract (Originalsprache)
Purpose FilmQADose is an open‐source, Python‐based software for radiochromic film dosimetry, designed to provide medical physicists with a freely available, extensible tool for two‐dimensional dose verification in radiotherapy. It covers the full film QA workflow, from calibration curve generation to plan‐to‐film comparison, targeting clinical and research centers that require an accessible alternative to commercial solutions. Development and Validation Methods The software was developed in Python using open‐source scientific libraries for image processing, curve fitting, DICOM handling, and gamma analysis. Core functionalities include rational and polynomial calibration models, multichannel dose reconstruction, normalized cross‐correlation template matching for automatic alignment, and gamma analysis. Validation was performed using irradiated Gafchromic EBT3 films in square field, pyramidal, and breast IMRT plans. Measured dose maps were compared against treatment planning system calculations using 3%/3 mm gamma criteria. Data Format and Usage Notes FilmQADose processes TIFF images acquired from flatbed scanners and DICOM RT Dose files exported from treatment planning systems. Output dose maps are generated in DICOM 2D format. The software is implemented in Python with standard scientific Python dependencies and includes a graphical user interface built using PySide6. The source code, documentation, and usage guides are publicly available at: eduardoh27.github.io/FilmQADose . Potential Applications The software supports clinical quality assurance in IMRT dose verification, as well as for research applications in radiochromic film dosimetry methodology. A limitation is the absence of lateral response artifact correction and recent machine‐learning‐based calibration methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Physics Department, Universidad de los Andes, Bogotá, Colombia.
- Centro de Control de Cáncer, Bogotá, Colombia.
ORCID-Profile: Eduardo Herrera-Alba, Juliana Sandoval-Navia, Carlos Ávila
Förderung
- Physics Department and the Faculty of Science of Universidad de los Andes, Bogotá
Zitieren
APA
Herrera-Alba, E., Contreras-Quiroz, C., Sandoval-Navia, J., Vásquez, J., & Ávila, C. (2026). FilmQADose: Open‐source software for radiochromic film dosimetry. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70602
Vancouver
Herrera-Alba E, Contreras-Quiroz C, Sandoval-Navia J, Vásquez J, Ávila C. FilmQADose: Open‐source software for radiochromic film dosimetry. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70602
BibTeX
@article{HerreraAlba2026,
author = {Herrera-Alba, Eduardo and Contreras-Quiroz, Carlos and Sandoval-Navia, Juliana and Vásquez, Jaider and Ávila, Carlos},
title = {FilmQADose: Open‐source software for radiochromic film dosimetry},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
doi = {10.1002/acm2.70602}
}