EUVIMEDEUVIMED entdecken
Crossref

Investigation of Factors Related to Operator’s Eye Lens Doses during Cardiac Catheterization Using a Specially Made Acrylic Phantom

Yoshinori Ogawa, Kosuke Matsubara, Thunyarat Chusin, Saori Shoji, Shigeto Matsuyama

Japanese Journal of Radiological Technology · 2025

DOI: 10.6009/jjrt.25-1513 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Japanese Journal of Radiological Technology, 2025. Verfasst von Yoshinori Ogawa und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Quantum Medical Technology, Graduate Course of Medical Science and Technology, Division of Health Sciences, Graduate School of Medical …. Hauptthemen laut MEDLINE: Phantoms, Imaging, Lens, Crystalline, Cardiac Catheterization, Radiation Dosage. Die Arbeit nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: We investigated the factors that influence the eye lens dose to the operator during cardiac catheterization using a cylindrical acrylic phantom, which can place small dosimeters at 3-mm depth from the surface. METHODS: A cylindrical acrylic phantom was placed on top of the thoracic phantom, which was used as the operator's phantom. The absorbed doses at the assumed positions of the eye lenses of the operator's phantom were measured by two irradiation modes. It was integrated from two projections in fluoroscopy mode. In cine mode, it was integrated from 15 projections. The measurement was performed by changing height of eye lenses (150, 165, and 180 cm), orientation of the cylindrical phantom (0°, 15°, 30°, and 45°), and the position of the operator's phantom (radial access, femoral access, and the position of the second operator). RESULTS: The lens doses decreased as the phantom height increased. The doses at the left neck were 1.2 to 1.4 times higher than those at the eye lens. The lens doses tended to decrease as the cylindrical phantom was oriented away from the X-ray tube, and it was the highest when the phantom was at the radial access approach position. CONCLUSIONS: During cardiac catheterization, the absorbed dose of the operator's lens depends on the operator's height, head orientation, and position. If the dosimeter is placed on the neck, the eye lens dose can be conservatively estimated.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingLens, CrystallineCardiac CatheterizationRadiation DosageOccupational ExposureHumansFluoroscopy

Stichwörter der Autor:innen

cardiac catheterizationeye lens doseradiation measurementradiation protection

Autor:innen und Institutionen

  • Department of Quantum Medical Technology, Graduate Course of Medical Science and Technology, Division of Health Sciences, Graduate School of Medical Science, Kanazawa University.
  • Department of Quantum Medical Technology, Faculty of Health Science, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University.
  • Department of Radiological Technology, Kanazawa University Hospital.

Zitieren

APA

Ogawa, Y., Matsubara, K., Chusin, T., Shoji, S., & Matsuyama, S. (2025). Investigation of Factors Related to Operator’s Eye Lens Doses during Cardiac Catheterization Using a Specially Made Acrylic Phantom. Japanese Journal of Radiological Technology. https://doi.org/10.6009/jjrt.25-1513

Vancouver

Ogawa Y, Matsubara K, Chusin T, Shoji S, Matsuyama S. Investigation of Factors Related to Operator’s Eye Lens Doses during Cardiac Catheterization Using a Specially Made Acrylic Phantom. Japanese Journal of Radiological Technology. 2025. doi:10.6009/jjrt.25-1513

BibTeX
@article{Ogawa2025,
  author = {Ogawa, Yoshinori and Matsubara, Kosuke and Chusin, Thunyarat and Shoji, Saori and Matsuyama, Shigeto},
  title = {Investigation of Factors Related to Operator’s Eye Lens Doses during Cardiac Catheterization Using a Specially Made Acrylic Phantom},
  journal = {Japanese Journal of Radiological Technology},
  year = {2025},
  doi = {10.6009/jjrt.25-1513}
}
Kostenlos starten →