Dose evaluation of medical staff during proximal femur fracture surgery using fluoroscopy

Luiz Matheus de Souza Aguiar Leite iD, Lilian Torres Rezende Ribeiro iD, Arícia Ravane Pereira da Cruz iD, Vinícius Saito Monteiro de Barros iD, Felipe Alves Monte iD, Thiago Henrique Silveira de Andrade iD, Júlio César Xavier Filho iD, Gabriela Rosa Meira iD, Viviane Khoury Asfora iD

Journal of Radiological Protection · 01.09.2026 · 46 (3) · 031508

DOI: 10.1088/1361-6498/ae7f2a ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Radiological Protection, online erschienen am 08.07.2026. Verfasst von Luiz Matheus de Souza Aguiar Leite und 8 weiteren Autor:innen. Beteiligte Einrichtung: Nuclear Energy Department, Federal University of Pernambuco, Av. Prof. Luiz Freire, 1000, Cidade Universitária, Recife, 50740-545 Pernambuco, Brazil. Hauptthemen laut MEDLINE: Occupational Exposure, Radiation Dosage, Proximal Femoral Fractures, Femoral Fractures. Die Arbeit nennt 41 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The use of fluoroscopy in orthopedic interventional procedures has become increasingly common. Although it offers significant clinical advantages by reducing procedural invasiveness, it also exposes both patients and medical staff to ionizing radiation. This study reports occupational dose measurements for surgeons during 40 proximal femur fracture procedures conducted at a reference hospital in Recife, Brazil. The estimated annual effective doses for the leading and auxiliary surgeons were approximately 1.3–1.5 mSv, corresponding to about 7.5% of the annual dose limit ( n = 325 procedures yr −1 ). The estimated annual eye lens exposures for both surgeons ranged from 4.7–5.8 mSv yr −1 , approaching 30% the current eye lens dose limit. For these procedures, the glabella (forehead) position was identified as the most appropriate location for the eye lens dosimeter. A correlation between H p (10) values measured externally on the thyroid shield and H p (3) doses at the glabella suggests that eye lens dose measurements can serve as a preliminary indicator—within ±15%–for determining the need for dedicated eye lens monitoring when annual lens doses may exceed 15 mSv. Dose measurements to the hands varied according to the procedure type and the equipment used. The highest values were observed during complex surgeries, such as complex subtrochanteric fractures with multiple fragments. The frequency of outliers in the hand dose data, observed in approximately 15% of the procedures, is associated with cases in which at least one of the surgeon’s hands was exposed to the primary beam. For the leading surgeon, the doses from outliers to the left hand accounted for 58% of the total dose to that hand, whereas for the auxiliary surgeon, 16% of procedures classified as high outliers contributed 75% of the total dose. These findings emphasise the importance of keeping hands outside the primary beam, as even brief direct exposures can significantly increase occupational hand doses.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Occupational ExposureRadiation DosageProximal Femoral FracturesFemoral FracturesHumansFluoroscopyLens, CrystallineBrazilRadiation ExposureRadiation Protection

Stichwörter der Autor:innen

Tl dosimetryinterventional radiologyoccupational dosimetryorthopedic proceduresproximal femur fracture

Autor:innen und Institutionen

  • Nuclear Energy Department, Federal University of Pernambuco, Av. Prof. Luiz Freire, 1000, Cidade Universitária, Recife, 50740-545 Pernambuco, Brazil.
  • Holy House of Mercy Hospital, Av. Cruz Cabugá, 1563, Santo Amaro, Recife, 50040-000 Pernambuco, Brazil.

ORCID-Profile: Luiz Matheus de Souza Aguiar Leite, Lilian Torres Rezende Ribeiro, Arícia Ravane Pereira da Cruz, Vinícius Saito Monteiro de Barros, Felipe Alves Monte, Thiago Henrique Silveira de Andrade, Júlio César Xavier Filho, Gabriela Rosa Meira, Viviane Khoury Asfora

Zitieren

APA

Leite, L. M. S. A., Ribeiro, L. T. R., Cruz, A. R. P. D., Barros, V. S. M., Monte, F. A., Andrade, T. H. S., Xavier Filho, J. C., Meira, G. R., & Khoury Asfora, V. (2026). Dose evaluation of medical staff during proximal femur fracture surgery using fluoroscopy. Journal of Radiological Protection, 46(3), 031508. https://doi.org/10.1088/1361-6498/ae7f2a

Vancouver

Leite LMSA, Ribeiro LTR, Cruz ARPD, Barros VSM, Monte FA, Andrade THS, et al. Dose evaluation of medical staff during proximal femur fracture surgery using fluoroscopy. Journal of Radiological Protection. 2026;46(3):031508. doi:10.1088/1361-6498/ae7f2a

BibTeX
@article{Leite2026,
  author = {Leite, Luiz Matheus de Souza Aguiar and Ribeiro, Lilian Torres Rezende and Cruz, Arícia Ravane Pereira da and Barros, Vinícius Saito Monteiro de and Monte, Felipe Alves and Andrade, Thiago Henrique Silveira de and Xavier Filho, Júlio César and Meira, Gabriela Rosa and Khoury Asfora, Viviane},
  title = {Dose evaluation of medical staff during proximal femur fracture surgery using fluoroscopy},
  journal = {Journal of Radiological Protection},
  year = {2026},
  volume = {46},
  number = {3},
  pages = {031508},
  doi = {10.1088/1361-6498/ae7f2a}
}
Kostenlos starten →