Radiation dose to the eye of physicians during radio frequency catheter ablation: a small-scale study
Irish Journal of Medical Science (1971 -) · 2024
DOI: 10.1007/s11845-024-03802-6 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Irish Journal of Medical Science (1971 -), 2024. Verfasst von Yoshiaki Morishima und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, Tohoku Medical and Pharmaceutical University Hospital, 1-12-1 Fukumuro, Miyagino-Ku, Sendai, 983-8512, Japan. …. Hauptthemen laut MEDLINE: Occupational Exposure, Radiation Dosage, Catheter Ablation, Lens, Crystalline. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tohoku Medical and Pharmaceutical University.
Abstract (Originalsprache)
Background
Radio frequency catheter ablation (RFCA), a treatment for arrhythmia, requires a long fluoroscopy time that increases the radiation exposure dose to the physician, particularly to the lens of the eye. It is recommended that a lens-specific dosimeter such as DOSIRIS® is used to measure the dose to the lens.
Aims
In this study, we investigated whether conventional glass badges can be used as an alternative to lens dosimeters.
Methods
The doses to the lenses of two physicians (physician A, main operator; physician B, assistant; physician B was further away from the patient than physician A) were measured for 126 RFCA procedures performed over a 6-month period (fluoroscopy rate of 3.0 p/s with use of a ceiling-hanging shield).
Results
The cumulative value measured by a lens dosimeter attached to the inside of Pb glasses (0.07-mm dose equivalent) next to the left eye was 4.7 mSv for physician A, and 0.8 mSv for physician B. The reading on the glass badge worn on the left side of the neck was 4.7 mSv for physician A and 1.3 mSv for physician B. Lens dosimeter and glass badge values showed a good correlation for the left eye and left neck ( r = 0.86, p < 0.01).
Conclusions
We show that glass badges may be a viable alternative to lens-equivalent dosimetry when using low-pulse fluoroscopy and a ceiling-hanging shield.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiological Technology, Tohoku Medical and Pharmaceutical University Hospital, 1-12-1 Fukumuro, Miyagino-Ku, Sendai, 983-8512, Japan. morishima@med.tohoku.ac.jp.
- Department of Radiological Technology, Tohoku University School of Health Sciences, Sendai, 980-8575, Japan. morishima@med.tohoku.ac.jp.
- Department of Radiological Technology, Tohoku University School of Health Sciences, Sendai, 980-8575, Japan.
- Department of Radiological Technology, Tohoku Medical and Pharmaceutical University Hospital, 1-12-1 Fukumuro, Miyagino-Ku, Sendai, 983-8512, Japan.
- Cardiac Center, Tohoku Medical and Pharmaceutical University Hospital, Sendai, 983-8512, Japan.
Förderung
- Tohoku Medical and Pharmaceutical University
Zitieren
APA
Morishima, Y., Chida, K., Chiba, H., & Kumagai, K. (2024). Radiation dose to the eye of physicians during radio frequency catheter ablation: a small-scale study. Irish Journal of Medical Science (1971 -). https://doi.org/10.1007/s11845-024-03802-6
Vancouver
Morishima Y, Chida K, Chiba H, Kumagai K. Radiation dose to the eye of physicians during radio frequency catheter ablation: a small-scale study. Irish Journal of Medical Science (1971 -). 2024. doi:10.1007/s11845-024-03802-6
BibTeX
@article{Morishima2024,
author = {Morishima, Yoshiaki and Chida, Koichi and Chiba, Hiroo and Kumagai, Koji},
title = {Radiation dose to the eye of physicians during radio frequency catheter ablation: a small-scale study},
journal = {Irish Journal of Medical Science (1971 -)},
year = {2024},
doi = {10.1007/s11845-024-03802-6}
}
EUVIMED