Eye lens dose in interventional cardiology personnel in Vietnam: direct Hp(3) measurement, indirect method comparison, and fluoroscopy-time-based dose estimation
Radiation Protection Dosimetry · 2026
DOI: 10.1093/rpd/ncag098 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Radiation Protection Dosimetry, 2026. Verfasst von Nham Thuy Thi Nguyen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Oncology and Nuclear Medicine, Military Hospital 175, 786 Nguyen Kiem Street, Ho Chi Minh City 71423, Vietnam. Hauptthemen laut MEDLINE: Lens, Crystalline, Occupational Exposure, Radiation Protection, Cardiology. Die Arbeit nennt 41 Literaturangaben.
Abstract (Originalsprache)
Personal dose equivalents Hp(3) in interventional cardiology personnel are of growing regulatory concern following International Commission on Radiological Protection (ICRP) Publication 118, which revised the occupational eye lens dose limit to 20 mSv/year. This prospective cohort study presents the first peer-reviewed direct Hp(3) dosimetry data from Vietnamese catheterization laboratory workers. Twelve personnel (eight physicians, four technicians) were monitored over 10 weeks (202 procedures, Siemens Artis Zee system), with doses extrapolated to 12 weeks. Direct Hp(3) ranged from 0.58–4.59 mSv (physicians) and 0.26–1.01 mSv (technicians); annualized projections reached 19.10 mSv/year, approaching the ICRP limit. Five physicians exceeded the 6 mSv/year International Radiation Protection Association investigation level. Indirect dosimetry (Swiss Society of Radiobiology and Medical Physics-SSRPM two-dosemeter algorithm) overestimated direct measurements by mean factors of 1.31 (physicians) and 1.68 (technicians). A strong dose–fluoroscopy time correlation was identified for physicians (R2 = 0.918). Direct Hp(3) monitoring and lead-equivalent eye protection are recommended.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Institute of Oncology and Nuclear Medicine, Military Hospital 175, 786 Nguyen Kiem Street, Ho Chi Minh City 71423, Vietnam.
- Faculty of Medicine, Nguyen Tat Thanh University, 300A Nguyen Tat Thanh Street, Ho Chi Minh City 75400, Vietnam.
- Center for Nuclear Technologies (CNT), Vietnam Atomic Energy Institute (VINATOM), 217 Nguyen Trai Street, Ho Chi Minh City 71014, Vietnam.
ORCID-Profile: Dung Manh Ho
Zitieren
APA
Nguyen, N. T. T., Pham, T. N., Tran, N. Y., Ta, H. A., Dang, L. T., & Ho, D. M. (2026). Eye lens dose in interventional cardiology personnel in Vietnam: direct Hp(3) measurement, indirect method comparison, and fluoroscopy-time-based dose estimation. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncag098
Vancouver
Nguyen NTT, Pham TN, Tran NY, Ta HA, Dang LT, Ho DM. Eye lens dose in interventional cardiology personnel in Vietnam: direct Hp(3) measurement, indirect method comparison, and fluoroscopy-time-based dose estimation. Radiation Protection Dosimetry. 2026. doi:10.1093/rpd/ncag098
BibTeX
@article{Nguyen2026,
author = {Nguyen, Nham Thuy Thi and Pham, Tuyen Nhu and Tran, Nhi Y and Ta, Hoang Anh and Dang, Luong Thanh and Ho, Dung Manh},
title = {Eye lens dose in interventional cardiology personnel in Vietnam: direct Hp(3) measurement, indirect method comparison, and fluoroscopy-time-based dose estimation},
journal = {Radiation Protection Dosimetry},
year = {2026},
doi = {10.1093/rpd/ncag098}
}
EUVIMED