EUVIMEDEUVIMED entdecken
Crossref

The Need for Lens Radiation Protection for Healthcare Provider in Open and Internal Fixation of the Hip Joint

Hiroki Matsumoto, Shoya Tokushige, Yasutaka Takei, Yuji Uyama, Masakatsu Mura, Go Hitomi

Japanese Journal of Radiological Technology · 2024

DOI: 10.6009/jjrt.2024-1422 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Japanese Journal of Radiological Technology, 2024. Verfasst von Hiroki Matsumoto und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, Kawasaki Medical School Hospital. Hauptthemen laut MEDLINE: Radiation Protection, Lens, Crystalline, Radiation Exposure, Occupational Exposure. Die Arbeit nennt 12 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Increased occupational exposure of radiation workers is a major problem during open reduction and internal fixation (ORIF) of the hip joint, as the surgeon's eye lens is in close proximity to the patient and the X-ray tube. The purposes of this study were to clarify the occupational exposure of radiation workers during ORIF of the hip joint and to examine the need for radiation protection measures. The radiation exposure of radiation workers was evaluated by making an airborne dose distribution map using phantom experiments. The radiation goggles attached with a small optically stimulated luminescence dosimeter were used in clinical practice to measure the lens dose received by the surgeon, and the necessity of radiation goggles was examined. The airborne dose distribution in ORIF of the hip joint showed a wider area of high dose rate during axial fluoroscopy of the femoral neck than during posterior-anterior fluoroscopy. In axial fluoroscopy of the femoral neck, the surgeon was always in the high dose rate range of 10 µGy/min or higher, the nurses were in the dose rate range of 4 to 10 µGy/min, and the radiologic technologists were in the dose rate range of 0.5 µGy/min or lower. The maximum 3 mm dose equivalent to the surgeon per case was 0.38 mSv. In contradiction, radiation goggles were useful in ORIF because they provided approximately 60% shielding. It is advisable to work with radiation goggles to avoid cataracts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation ProtectionLens, CrystallineRadiation ExposureOccupational ExposureHumansHip JointHealth PersonnelRadiation DosageFluoroscopy

Stichwörter der Autor:innen

ORIFlens doseoccupational exposureradiation protection

Autor:innen und Institutionen

  • Department of Radiological Technology, Kawasaki Medical School Hospital.
  • Department of Radiological Technology, Kawasaki University of Medical Welfare.

Zitieren

APA

Matsumoto, H., Tokushige, S., Takei, Y., Uyama, Y., Mura, M., & Hitomi, G. (2024). The Need for Lens Radiation Protection for Healthcare Provider in Open and Internal Fixation of the Hip Joint. Japanese Journal of Radiological Technology. https://doi.org/10.6009/jjrt.2024-1422

Vancouver

Matsumoto H, Tokushige S, Takei Y, Uyama Y, Mura M, Hitomi G. The Need for Lens Radiation Protection for Healthcare Provider in Open and Internal Fixation of the Hip Joint. Japanese Journal of Radiological Technology. 2024. doi:10.6009/jjrt.2024-1422

BibTeX
@article{Matsumoto2024,
  author = {Matsumoto, Hiroki and Tokushige, Shoya and Takei, Yasutaka and Uyama, Yuji and Mura, Masakatsu and Hitomi, Go},
  title = {The Need for Lens Radiation Protection for Healthcare Provider in Open and Internal Fixation of the Hip Joint},
  journal = {Japanese Journal of Radiological Technology},
  year = {2024},
  doi = {10.6009/jjrt.2024-1422}
}
Kostenlos starten →