Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2025. Verfasst von Munehiko Kowatari und 10 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Radiological Science, National Institutes for Quantum Science and Technology (QST), 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555 Japan. Hauptthemen laut MEDLINE: Occupational Exposure, Radiation Monitoring, Radiation Protection, Radiation Dosimeters. Die Arbeit nennt 10 Literaturangaben. Gefördert von: JSPS, Ministry of Health, Labour and Welfare, Japan.
Abstract (Originalsprache)
It is crucial to monitor healthcare workers’ radiation exposure, especially given the increasing reliance on X-ray imaging technologies. In response to new evidence that the threshold for lens opacity is lower than previously thought, the International Commission on Radiological Protection (ICRP) has revised the annual dose limit for exposure to the lens of the eye. After the revision of the annual eye lens dose limit, the new survey on the dosemeter wearing rate was conducted in Japan. The result showed that despite the presence of monitoring protocols, the dosemeter wearing rate among healthcare workers was still low. Compliance often lacked robust verification measures, especially in smaller medical facilities. Active personal dosemeters (APDs) are commonly used in Japan, although studies suggest that they may underestimate exposure in certain settings, such as pulsed X-ray fields. Passive dosemeters, on the other hand, serve as legal dosemeters, offering a more accurate assessment of radiation exposure. This article addresses issues related to the monitoring of healthcare workers using APDs and clarifies concerns regarding the use of APDs by orthopedic surgeons during procedures involving high-dose X-ray exposure. A series of performance tests suggested that the APDs worn by orthopedic surgeons, who are often exposed to higher dose rates near patients, may underestimate radiation levels during procedures. This underestimation occurs because the surgeons are exposed to pulsed, scattered X-ray fields with energies ranging from 20 and 100 keV. The results also suggest monitoring techniques should be improved to ensure the safety of healthcare workers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Institute of Radiological Science, National Institutes for Quantum Science and Technology (QST), 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555 Japan.
- University of Occupational and Environmental Health Japan, Kitakyushu, 807-8555, Japan.
- Department of Healthcare Epidemiology, School of Public Health in the Graduate School of Medicine, Kyoto University, Kyoto, Japan.
- Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan.
- Department of Radiation Protection, Nuclear Science Research Institute Japan Atomic Energy Agency, 2-4, Shirakata, Tokai, Naka, Ibaraki 319-1195, Japan.
- Physikalisch-Technische Bundesanstalt Bundesallee 100, 38116, Braunschweig, Germany.
Förderung
- JSPS
- Ministry of Health, Labour and Welfare, Japan
Zitieren
APA
Kowatari, M., Nakagami, K., Hijikata, Y., Yamashita, K., Hirai, Y., Matsuzaki, S., Moritake, T., Tsuji, T., Zutz, H., Ketelhut, S., & Hupe, O. (2025). Issues in monitoring orthopedic surgeons with active personal dosemeters when exposed to pulsed X-ray fields during orthopedic procedures. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncaf061
Vancouver
Kowatari M, Nakagami K, Hijikata Y, Yamashita K, Hirai Y, Matsuzaki S, et al. Issues in monitoring orthopedic surgeons with active personal dosemeters when exposed to pulsed X-ray fields during orthopedic procedures. Radiation Protection Dosimetry. 2025. doi:10.1093/rpd/ncaf061
BibTeX
@article{Kowatari2025,
author = {Kowatari, Munehiko and Nakagami, Koichi and Hijikata, Yasukazu and Yamashita, Kazuta and Hirai, Yuta and Matsuzaki, Satoru and Moritake, Takashi and Tsuji, Tomoya and Zutz, Hayo and Ketelhut, Steffen and Hupe, Oliver},
title = {Issues in monitoring orthopedic surgeons with active personal dosemeters when exposed to pulsed X-ray fields during orthopedic procedures},
journal = {Radiation Protection Dosimetry},
year = {2025},
doi = {10.1093/rpd/ncaf061}
}
EUVIMED