The effectiveness of an educational program for reducing radiation exposure to the lens of the eye in radiological technologists: focusing on patient assistance during chest X-ray examinations
Radiation Protection Dosimetry · 2026
DOI: 10.1093/rpd/ncaf158 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2026. Verfasst von Mitsuyoshi Yasuda und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Therapy, Showa University School of Nursing and Rehabilitation Sciences, 1865 Tokaichiba-cyo, Midori-ku, Yokohama, Kanagawa 22…. Hauptthemen laut MEDLINE: Radiation Protection, Occupational Exposure, Radiation Exposure, Lens, Crystalline. Die Arbeit nennt 26 Literaturangaben.
Abstract (Originalsprache)
Radiation exposure risk to the lens of the eye varies based on where technologists assist during chest X-rays. In this study five radiologic technologists participated in the training for lens exposure reduction methods proposed in previous studies, and the personal dose equivalent at a depth of 3 mm [Hp(3)] near the eyes were evaluated. Data were collected before and after the training. After the training, three radiologic technologists had 3%–27% decreases in Hp(3) at the measurement points, and the proportion of selecting the assistance position with the lowest Hp(3) increased. However, one technologist with extensive experience in chest X-ray examinations showed no significant differences in Hp(3) before and after the training. This suggests that the training is specifically effective for technologists with less experience in radiation-related work because the radiation protection education brought about behavioral changes in the radiologic technologists, leading to a reduction in their Hp(3).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Physical Therapy, Showa University School of Nursing and Rehabilitation Sciences, 1865 Tokaichiba-cyo, Midori-ku, Yokohama, Kanagawa 226-8555, Japan.
- Department of Radiological Technology, Showa Medical University Fujigaoka Hospital, 1-30 Fujigaoka Aoba-ku, Yokohama, Kanagawa 227-8501, Japan.
- Department of Radiological Technology, Showa Medical University Hospital, 1-5-8 Hatanodai Shinagawa-ku, Tokyo 142-8666, Japan.
- Division of Health Science Education, Showa Medical University School of Nursing and Rehabilitation Sciences, 1865 Tokaichiba-cyo, Midori-ku, Yokohama, Kanagawa 226-8555, Japan.
- Department of Administration, Showa Medical University Hospital, 1-5-8 Hatanodai Shinagawa-ku, Tokyo 142-8666, Japan.
ORCID-Profile: Mitsuyoshi Yasuda, Tomoki Fuji
Zitieren
APA
Yasuda, M., Fuji, T., Hondera, T., Watanabe, H., Yamabe, K., Goto, M., Sato, H., Ishizaki, K., & Enokida, M. (2026). The effectiveness of an educational program for reducing radiation exposure to the lens of the eye in radiological technologists: focusing on patient assistance during chest X-ray examinations. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncaf158
Vancouver
Yasuda M, Fuji T, Hondera T, Watanabe H, Yamabe K, Goto M, et al. The effectiveness of an educational program for reducing radiation exposure to the lens of the eye in radiological technologists: focusing on patient assistance during chest X-ray examinations. Radiation Protection Dosimetry. 2026. doi:10.1093/rpd/ncaf158
BibTeX
@article{Yasuda2026,
author = {Yasuda, Mitsuyoshi and Fuji, Tomoki and Hondera, Tetsuichi and Watanabe, Hiroyuki and Yamabe, Kanako and Goto, Mitsunori and Sato, Hisaya and Ishizaki, Kenji and Enokida, Megumi},
title = {The effectiveness of an educational program for reducing radiation exposure to the lens of the eye in radiological technologists: focusing on patient assistance during chest X-ray examinations},
journal = {Radiation Protection Dosimetry},
year = {2026},
doi = {10.1093/rpd/ncaf158}
}
EUVIMED