Effects of Phantom Factor on Shape Differences in Tomotherapy Water-equivalent Phantoms
Japanese Journal of Radiological Technology · 2023
DOI: 10.6009/jjrt.2023-1233 ↗Kurz gefasst
Fachartikel in der Zeitschrift Japanese Journal of Radiological Technology, 2023. Verfasst von Koji Ishita und 9 weiteren Autor:innen. Beteiligte Einrichtung: Central Radiology, Aomori Rosai Hospital. Hauptthemen laut MEDLINE: Water, Radiotherapy, Intensity-Modulated. Die Arbeit nennt 15 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: The purpose of this study was to evaluate the effects of phantom factor on the verification of measured doses using cheese phantoms in tomotherapy. METHODS: Two plans for dose verification (plan classes and plan class phantom sets with a virtual organ at the risk set) were evaluated. The calculated and measured doses were compared with and without the phantom factor using cheese phantoms. Additionally, the phantom factor was evaluated for two conditions (TomoHelical/TomoDirect) in clinical cases (breast and prostate). RESULTS: When applying a phantom factor of 1.007, the deviation between the calculated and measured doses increased in Plan-Class and TomoDirect, decreased in TomoHelical, and increased in both clinical cases. CONCLUSION: When conducting dose verification, the effects of one phantom factor on measurement conditions may differ depending on when phantom factors were obtained (irradiation technique and irradiation field). It is therefore necessary to consider changes in measured doses due to changes in phantom scattering.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Central Radiology, Aomori Rosai Hospital.
- Department of Radiological Technology, Graduate School of Health Sciences, Okayama University.
- Department of Radiological Technology, Jinsenkai Kita-Fukushima Medical Center.
- Department of Radiology, Fukushima Medical University Hospital.
Zitieren
APA
Ishita, K., Tanabe, Y., Sawahashi, M., Yonaiguchi, J., Takeda, M., Sokawa, T., Suenaga, M., Abe, K., Suzuki, R., & Sato, Y. (2023). Effects of Phantom Factor on Shape Differences in Tomotherapy Water-equivalent Phantoms. Japanese Journal of Radiological Technology. https://doi.org/10.6009/jjrt.2023-1233
Vancouver
Ishita K, Tanabe Y, Sawahashi M, Yonaiguchi J, Takeda M, Sokawa T, et al. Effects of Phantom Factor on Shape Differences in Tomotherapy Water-equivalent Phantoms. Japanese Journal of Radiological Technology. 2023. doi:10.6009/jjrt.2023-1233
BibTeX
@article{Ishita2023,
author = {Ishita, Koji and Tanabe, Yoshinori and Sawahashi, Masami and Yonaiguchi, Junichi and Takeda, Miyuki and Sokawa, Takahiro and Suenaga, Masafumi and Abe, Kazuya and Suzuki, Ryousuke and Sato, Yuuki},
title = {Effects of Phantom Factor on Shape Differences in Tomotherapy Water-equivalent Phantoms},
journal = {Japanese Journal of Radiological Technology},
year = {2023},
doi = {10.6009/jjrt.2023-1233}
}
EUVIMED