Background

Denture base resins play a critical role in the longevity and clinical success of removable prostheses. Conventional heat-cured polymethyl methacrylate (PMMA) has long been the material of choice; however, the advent of 3D printing technology has introduced alternative materials with potential advantages in fabrication efficiency and customization. Despite these benefits, concerns remain regarding their mechanical properties.

Aim

To compare the mechanical strength of 3D-printed denture base resins with conventional heat-cured denture base resins. Materials and Methods: This in vitro study was conducted using standardized rectangular specimens fabricated from two groups: Group I – heat-cured PMMA denture base resin and Group II – 3D-printed denture base resin. Each group consisted of equal numbers of samples prepared according to manufacturer specifications. Mechanical strength was evaluated using a three-point bending test on a universal testing machine to determine flexural strength. The obtained data were statistically analyzed using an independent t-test, with the level of significance set at p < 0.05.

Results

The heat-cured PMMA group demonstrated higher mean flexural strength compared to the 3D-printed resin group. The difference between the groups was found to be statistically significant (p < 0.05), indicating superior mechanical performance of conventional denture base material under the tested conditions.

Conclusion

Within the limitations of this study, heat-cured denture base resins exhibited greater mechanical strength than 3D-printed resins. However, 3D-printed materials offer advantages in terms of fabrication and digital workflow, suggesting the need for further advancements to enhance their mechanical properties for long-term clinical application.

Zitieren

APA

Singh, A., Chaiwala, A. H., Debbarma, M., Sagar, S., Gupta, A., & Rajan, M. (2026). A Comparative Study On The Mechanical Strength Of 3D-Printed Versus Heat Cured Denture Base Resins. Academia Journal of Medicine, 9(1), 170-173. https://doi.org/10.48165/ajm.2026.9.01.35

Vancouver

Singh A, Chaiwala AH, Debbarma M, Sagar S, Gupta A, Rajan M. A Comparative Study On The Mechanical Strength Of 3D-Printed Versus Heat Cured Denture Base Resins. Academia Journal of Medicine. 2026;9(1):170-173. doi:10.48165/ajm.2026.9.01.35

BibTeX
@article{Singh2026,
  author = {Singh, Ankita and Chaiwala, Arwa Hussain and Debbarma, Malay and Sagar, Sai and Gupta, Ayushi and Rajan, Milind},
  title = {A Comparative Study On The Mechanical Strength Of 3D-Printed Versus Heat Cured Denture Base Resins},
  journal = {Academia Journal of Medicine},
  year = {2026},
  volume = {9},
  number = {1},
  pages = {170--173},
  doi = {10.48165/ajm.2026.9.01.35}
}
Kostenlos starten →