EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Mechanical, Optical, and Biofilm Accumulation Properties of Heat-Cured, CAD-CAM, and 3D-Printed Denture Base Resins After Simulated Brushing

Carlos Roberto Teixeira Rodrigues, Plinio Mendes Senna, Rachel Leite Ribeiro, Waldimir Rocha de Carvalho, Yuri Victor Lahud, Edgard de Mello Fonseca

Pesquisa Brasileira em Odontopediatria e Clínica Integrada · 2026 · 26

DOI: 10.1590/pboci.2026.121 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pesquisa Brasileira em Odontopediatria e Clínica Integrada, 2026. Verfasst von Carlos Roberto Teixeira Rodrigues und 5 weiteren Autor:innen. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the effects of simulated brushing on Candida albicans biofilm formation, surface roughness, hardness, mass loss, and color stability of denture base resins fabricated using different materials. Material and Methods: The study included three groups of resins: heat-cured PMMA (Vipicril Plus), CAD-CAM milled PMMA (Ivotion Base), and 3D-printed resin (Cosmos Denture), with 10 samples per group. Surface roughness, Vickers hardness, mass loss, color change (∆E00), and Candida albicans biofilm formation were measured before and after brushing. Statistical analyses were conducted using ANOVA and Tukey's post-hoc tests at a significance level of 5%.

Results

Heat-cured resin exhibited lower hardness values compared to milled resin (p < 0.05), while the hardness of the 3D-printed resin showed more significant variability (p > 0.05). The 3D-printed resin had the lowest surface roughness values before and after brushing (p < 0.05). In contrast, heat-cured resin demonstrated minimal color change and mass loss (p < 0.05). Candida albicans biofilm formation was lower on 3D-printed resin before brushing, although no significant difference was noted post-brushing.

Conclusion

Simulated brushing significantly altered the optical and mechanical properties of all resins. Heat-cured resin showed superior color stability and resistance to mass loss, while 3D-printed resin demonstrated the lowest surface roughness but higher biofilm formation after brushing.

Zitieren

APA

Rodrigues, C. R. T., Senna, P. M., Ribeiro, R. L., Carvalho, W. R. D., Lahud, Y. V., & Fonseca, E. D. M. (2026). Mechanical, Optical, and Biofilm Accumulation Properties of Heat-Cured, CAD-CAM, and 3D-Printed Denture Base Resins After Simulated Brushing. Pesquisa Brasileira em Odontopediatria e Clínica Integrada, 26. https://doi.org/10.1590/pboci.2026.121

Vancouver

Rodrigues CRT, Senna PM, Ribeiro RL, Carvalho WRD, Lahud YV, Fonseca EDM. Mechanical, Optical, and Biofilm Accumulation Properties of Heat-Cured, CAD-CAM, and 3D-Printed Denture Base Resins After Simulated Brushing. Pesquisa Brasileira em Odontopediatria e Clínica Integrada. 2026;26. doi:10.1590/pboci.2026.121

BibTeX
@article{Rodrigues2026,
  author = {Rodrigues, Carlos Roberto Teixeira and Senna, Plinio Mendes and Ribeiro, Rachel Leite and Carvalho, Waldimir Rocha de and Lahud, Yuri Victor and Fonseca, Edgard de Mello},
  title = {Mechanical, Optical, and Biofilm Accumulation Properties of Heat-Cured, CAD-CAM, and 3D-Printed Denture Base Resins After Simulated Brushing},
  journal = {Pesquisa Brasileira em Odontopediatria e Clínica Integrada},
  year = {2026},
  volume = {26},
  doi = {10.1590/pboci.2026.121}
}