Fachartikel in der Zeitschrift Tomography, online erschienen am 06.07.2026. Verfasst von Farroch Vahidi Noghani und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Ger…. Hauptthemen laut MEDLINE: Radiomics, Tomography, X-Ray Computed, Phantoms, Imaging, Image Processing, Computer-Assisted. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Carl Zeiss Foundation, Carl Zeiss Foundation Heidelberg.
Abstract (Originalsprache)
Objectives
This study investigates the repeatability and reproducibility of radiomic features extracted from different energy levels of virtual monoenergetic reconstruction (VMER) and polyenergetic reconstruction (PER) obtained with photon-counting computed tomography (PCCT).
Methods
Sixteen organic phantoms were scanned twice in a test–retest format using a 120 kV tube potential and tube currents of 10, 50, and 100 mAs. After rotating the phantoms 90° around their z-axis, additional test–retest scans were performed. A PER and 16 VMERs were generated. Segmentation and extraction of 105 original radiomic features followed. The repeatability and reproducibility of these features were assessed using the concordance correlation coefficient (CCC) for agreement and the intraclass correlation coefficient (ICC) for reliability, excluding 14 shape-based features from the analysis.
Results
On average, 85 out of 91 radiomic features from VMER showed high repeatability. Approximately 30% of features demonstrated high intra-scan and inter-scan reproducibility when comparing PER and VMER. For different energy levels of VMER, around 78% showed high intra-scan reproducibility, and 74% showed high inter-scan reproducibility. Comparing the average values of test and retest scans in both the initial and rotated states revealed that 65% of features showed high agreement and 73% high reliability for PER, while for VMER, these values were 51% and 55%, respectively.
Conclusions
Radiomic features from VMERs showed high test–retest repeatability, whereas reproducibility across reconstruction types and widely separated energy levels was more limited. These findings suggest that energy levels should be carefully standardized when radiomic features are extracted from PCCT-derived VMER images.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany.
- Department of Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.
ORCID-Profile: Farroch Vahidi Noghani, Matthias F Froelich, Alexander Hertel
Förderung
- Carl Zeiss Foundation
- Carl Zeiss Foundation Heidelberg
Zitieren
APA
Vahidi Noghani, F., Rotkopf, L. T., Schoenberg, S. O., Froelich, M. F., Ayx, I., & Hertel, A. (2026). Impact of Different Energy Levels of Virtual Monoenergetic Reconstructions on Radiomic Features Stability in Organic Phantom Imaging Using Photon-Counting CT. Tomography, 12(7), 102. https://doi.org/10.3390/tomography12070102
Vancouver
Vahidi Noghani F, Rotkopf LT, Schoenberg SO, Froelich MF, Ayx I, Hertel A. Impact of Different Energy Levels of Virtual Monoenergetic Reconstructions on Radiomic Features Stability in Organic Phantom Imaging Using Photon-Counting CT. Tomography. 2026;12(7):102. doi:10.3390/tomography12070102
BibTeX
@article{VahidiNoghani2026,
author = {Vahidi Noghani, Farroch and Rotkopf, Lukas T and Schoenberg, Stefan O and Froelich, Matthias F and Ayx, Isabelle and Hertel, Alexander},
title = {Impact of Different Energy Levels of Virtual Monoenergetic Reconstructions on Radiomic Features Stability in Organic Phantom Imaging Using Photon-Counting CT},
journal = {Tomography},
year = {2026},
volume = {12},
number = {7},
pages = {102},
doi = {10.3390/tomography12070102}
}
EUVIMED