Optimization of the reconstruction kernel for temporal bone imaging using photon-counting detector CT: A combined physical and visual evaluation
Radiography · 2026
DOI: 10.1016/j.radi.2025.103274 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiography, 2026. Verfasst von S Nishii und 11 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Health Sciences, Okayama University, Okayama, 700-8558, Japan. Electronic address: nishisou0810@gmail.com. Hauptthemen laut MEDLINE: Temporal Bone, Tomography, X-Ray Computed, Radiographic Image Interpretation, Computer-Assisted, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hitachi Global Foundation, Kurata Grants.
Abstract (Originalsprache)
INTRODUCTION: Photon-counting detector CT (PCD-CT) offers superior spatial resolution and noise characteristics compared to conventional CT. However, optimal reconstruction parameters for temporal bone imaging, especially kernel selection, remain unclear. This study aimed to identify the optimal reconstruction kernel using both objective physical image quality metrics and subjective expert assessments. METHODS: In phantom experiments, the system performance function (SPF) based on the task-based transfer function (TTF) and noise power spectrum (NPS) was calculated across 11 reconstruction kernels (Hr60-Hr98). Based on the results of the physical evaluation and clinical considerations from clinical practice, a subset of kernels was selected for visual assessment. For clinical images, two diagnostic radiologists evaluated three fine anatomical structures (i.e., stapes footplate, incudomalleolar joint, and cochlea) and overall image quality using both a ranking method and a 5-point Likert scale. RESULTS: TTF analysis indicated that Hr96 had the highest spatial resolution, while Hr60 showed the lowest noise in the NPS. SPF analysis identified Hr72 as providing the optimal balance between resolution and noise. Visual assessment using four reconstruction kernels (Hr60, Hr72, Hr76, and Hr84) showed that Hr76 consistently received the highest preference for overall image quality and visualization of fine structures. Statistically significant differences were observed among the kernels, with Hr60 consistently rated the lowest (p < 0.05). CONCLUSION: The kernel Hr76 was found suitable for middle and inner ear diagnoses using PCD-CT, providing a good balance between spatial resolution and image noise. This finding provides a foundation for standardized reconstruction protocols in high-resolution temporal bone imaging. IMPLICATIONS FOR PRACTICE: These findings support the use of Hr76 as a standard kernel for high-resolution temporal bone imaging and may contribute to protocol optimization in clinical PCD-CT practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Graduate School of Health Sciences, Okayama University, Okayama, 700-8558, Japan. Electronic address: nishisou0810@gmail.com.
- Department of Radiological Technology, Faculty of Health Sciences, Okayama University, Okayama, 700-8558, Japan. Electronic address: t-asahara@okayama-u.ac.jp.
- Division of Radiological Technology, Medical Support Department, Okayama University Hospital, Okayama, 700-8558, Japan. Electronic address: morimi-y@cc.okayama-u.ac.jp.
- Division of Radiological Technology, Medical Support Department, Okayama University Hospital, Okayama, 700-8558, Japan. Electronic address: kajisaki0728@okayama-u.ac.jp.
- Division of Radiological Technology, Medical Support Department, Okayama University Hospital, Okayama, 700-8558, Japan. Electronic address: atanuki1115@gmail.com.
- Division of Radiological Technology, Medical Support Department, Okayama University Hospital, Okayama, 700-8558, Japan. Electronic address: honda-m@cc.okayama-u.ac.jp.
Förderung
- Hitachi Global Foundation
- Kurata Grants
Zitieren
APA
Nishii, S., Asahara, T., Morimitsu, Y., Kajisaki, S., Akagi, N., Honda, M., Hayashi, H., Sugaya, A., Munetomo, K., Higaki, F., Hiraki, T., & Iguchi, T. (2026). Optimization of the reconstruction kernel for temporal bone imaging using photon-counting detector CT: A combined physical and visual evaluation. Radiography. https://doi.org/10.1016/j.radi.2025.103274
Vancouver
Nishii S, Asahara T, Morimitsu Y, Kajisaki S, Akagi N, Honda M, et al. Optimization of the reconstruction kernel for temporal bone imaging using photon-counting detector CT: A combined physical and visual evaluation. Radiography. 2026. doi:10.1016/j.radi.2025.103274
BibTeX
@article{Nishii2026,
author = {Nishii, S and Asahara, T and Morimitsu, Y and Kajisaki, S and Akagi, N and Honda, M and Hayashi, H and Sugaya, A and Munetomo, K and Higaki, F and Hiraki, T and Iguchi, T},
title = {Optimization of the reconstruction kernel for temporal bone imaging using photon-counting detector CT: A combined physical and visual evaluation},
journal = {Radiography},
year = {2026},
doi = {10.1016/j.radi.2025.103274}
}
EUVIMED