Coronary artery calcium scoring: expanding the new standard by photon-counting detector CT—Part I: Impact of tube voltage, tube current, slice thickness, and quantum iterative reconstructions
European Radiology · 2026
DOI: 10.1007/s00330-026-12355-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Radiology, 2026. Verfasst von Nicola Fink und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA. Hauptthemen laut MEDLINE: Coronary Artery Disease, Tomography, X-Ray Computed, Radiographic Image Interpretation, Computer-Assisted, Calcinosis. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Grant from Siemens Healthineers.
Abstract (Originalsprache)
Objectives
Coronary artery calcium (CAC) scoring is a well-established method for cardiovascular risk assessment but has limited reproducibility. For energy-integrating detector (EID)-CT, a new, multivendor validated protocol has been proposed. This study aimed to investigate the variability of photon-counting detector (PCD)-CT-based CAC scoring and propose a new protocol with decreased variability. Materials and methods A chest phantom containing nine calcifications was scanned on a PCD-CT using various settings: tube voltages (90 kVp, 120 kVp), tube currents (100% to 25% dose), slice thickness (3 mm, 1 mm), quantum iterative reconstruction (IR, 1–4). To evaluate interscan variability, phantoms were scanned five times per protocol with slight translational (5 mm) and rotational (2°) movements. The standard PCD-CT protocol used 120 kVp, 100% dose, 3 mm slices. CAC scores, image noise, and calcification detectability were assessed. Results were compared to the standard PCD-CT, and standard and proposed EID-CT protocols.
Results
Compared to the standard PCD-CT protocol, score variability decreased by 37% using a thin-sliced protocol at 120 kVp, 25% dose reduction and IR2. Compared to the proposed EID-CT protocol, variability was 66% lower. The optimized PCD-CT protocol met noise targets, eliminating the risk of false-positives. While 6.0 ± 0.0 and 7.0 ± 0.4 calcifications were detected using the PCD-CT standard and the proposed EID-CT protocol, respectively, 7.1 ± 0.7 calcifications were detected with the optimized PCD-CT protocol. Volume and mass scores were closer to physical reference.
Conclusions
A thin-slice, 25%-dose-reduced PCD-CT protocol at 120 kVp improves CAC score reproducibility and outperforms the proposed EID-CT protocol, possibly offering more reproducible CAC quantification at lower radiation doses. Key Points Question Coronary artery calcium scoring is used for cardiovascular risk stratification. However, the current standard method lacks score reproducibility.
Findings
A thin-slice, 25%-dose-reduced photon-counting detector CT protocol at 120 kVp significantly reduces score variability compared to previous protocols, including the proposed energy-integrating detector CT protocol. Clinical relevance Improved reproducibility of coronary artery calcium scoring may enable more consistent cardiovascular risk prediction and provide a robust technical basis for further in vivo studies. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA.
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany.
- Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA.
- Department of Radiology, Medical Imaging Centre, Semmelweis University, Budapest, Hungary.
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary.
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany.
Förderung
- Research Grant from Siemens Healthineers
Zitieren
APA
Fink, N., Koetzier, L. R., Zsarnoczay, E., Vecsey-Nagy, M., Kravchenko, D., Hagar, M. T., O'Doherty, J., Halfmann, M. C., Suranyi, P., van Praagh, G. D., Ricke, J., Maurovich-Horvat, P., Bäuerle, T., Willemink, M. J., Varga-Szemes, A., & Emrich, T. (2026). Coronary artery calcium scoring: expanding the new standard by photon-counting detector CT—Part I: Impact of tube voltage, tube current, slice thickness, and quantum iterative reconstructions. European Radiology. https://doi.org/10.1007/s00330-026-12355-4
Vancouver
Fink N, Koetzier LR, Zsarnoczay E, Vecsey-Nagy M, Kravchenko D, Hagar MT, et al. Coronary artery calcium scoring: expanding the new standard by photon-counting detector CT—Part I: Impact of tube voltage, tube current, slice thickness, and quantum iterative reconstructions. European Radiology. 2026. doi:10.1007/s00330-026-12355-4
BibTeX
@article{Fink2026,
author = {Fink, Nicola and Koetzier, Lennart R and Zsarnoczay, Emese and Vecsey-Nagy, Milan and Kravchenko, Dmitrij and Hagar, Muhammad Taha and O'Doherty, Jim and Halfmann, Moritz C and Suranyi, Pal and van Praagh, Gijs D and Ricke, Jens and Maurovich-Horvat, Pal and Bäuerle, Tobias and Willemink, Martin J and Varga-Szemes, Akos and Emrich, Tilman},
title = {Coronary artery calcium scoring: expanding the new standard by photon-counting detector CT—Part I: Impact of tube voltage, tube current, slice thickness, and quantum iterative reconstructions},
journal = {European Radiology},
year = {2026},
doi = {10.1007/s00330-026-12355-4}
}
EUVIMED